Using Spectrum Analyzer Features
Use the Marker Table to List All the Active Markers
Example: Use the marker table to measure the calibrator signal.
1.Connect the CAL OUT signal to the cable TV analyzer’s INPUT 75 0. Press
2.Press (PEAK SEARCH) and NEXT PK RIGHT to place the marker 1 on the 300 MHz ca.l signal.
3.Press CMKRj, MK TA3LE ON OFF (ON) to turn on the marker table function.
4.Press (MKR) SELECT 1 2 3 4 (2) to select marker 2. Press
MARKER OH OFF (ON) to activate marker 2. Use the NEXT PK RIGHT key, or move the marker using the key pad or knob to place marker 2 on the next harmonic. Repeat the process for markers 3 and 4.
5.Make marker 2 readout time, rather than frequency, by pressing LMKR) and pressing SELECT 1 2 3 4 until 2 is selected (underlined). Press
More 1 of 2 , MK READ F T I P (T) to select time for the marker readout.
6.The marker table can be set to display the marker amplitudes relative to the display line. Press
N O T E
The marker table data can be printed by pressing the (COPYI) key.
The marker table cannot be saved or recalled.