Making Measurements Using Spectrum Analyzer Made

Using the Power Measurement Functions to make Transmitter Measurements

Channel Power Measurement

The channel power function measures the total power in the selected channel bandwidth. The signal can be noise, tones, or a combination of noise and tones. The channel power function measures the power using an rms method. Enter the channel bandwidth and activate the channel power measurement. The spectrum analyzer calculates and displays:

The total power in dBmV (other units selectable)

The power spectral density in dBmV/Hz (other units selectable)

Example: Measure the total power in a signal

1.Connect a signal to the spectrum analyzer’s INPUT 75 Q.

2.Press [FREQUENCY] and enter the frequency of your input signal to place the signal at the spectrum-analyzer center frequency.

3.Press [AMPLITUDE) and adjust the reference level to bring the signal near the top of the display.

4.Press [MEAS~USER] and Power Menu to access the power measurement

functions. Press Setup and CHANNEL BANDWDTH Enter the value for the channel bandwidth. (The spectrum analyzer will use the last entered value for channel bandwidth, if it is not entered.)

5.Press CHANNEL SPACING and enter the value for channel spacing. (This is optional and is only used to set the center frequency step size.)

5-74