Using Spectrum Analyzer Features

Saving and Recalling Data from the Memory Card

To Save a Trace

Saving trace data saves the trace data and the state data.

1.Press (jj] or CCONFIGI), and then Change Prefix to enter a new preEx or change the existing preEx.

If you do not specify a preEx, the trace will be saved with a Ele name consisting of s-(register number).

2.Enter a screen title, if desired, by using @iFiF] then Change Title

3.Set up the trace to be stored.

4.Press (SAVE). If INTERNAL is underlined, press INTERNAL CARD to select CARD. Press Trace -+ Card to access the menu that displays TRACE A , TRACE B , and TRACE C .

5.Press the softkey label of the trace that you want to save: TRACE A ,

TRACE 3 , or TRACE C . REGISTER # and PREFIX= are displayed on the cable TV analyzer display.

6.Use the numeric keypad to enter a register number and then press (ENTER).

The trace data is saved with a file name consisting of a “t, )) the current preEx, an underscore (-), and the register number. The “t” denotes that the file contains trace data.

3-22