3 Lines/Trunks

 

Selecting Line/Trunk Options

Page 3-19

 

 

For detailed information about these options, see the Feature Reference.

You may want to assign remote access to only a few trunks and increase the number later if more are needed.

NOTES:

1.If you want to allow remote access on DID trunks, the routing digits supplied by the central office must match the factory-set remote access code (889) or the remote access code assigned to the system in the following procedure.

2.Trunks programmed for both remote access and Group Calling will receive remote access treatment only.

3.Remote access callers may not log in to a calling group but may call the calling group by dialing the group access number.

4.Private network calls may use the Remote Access feature if the remote access code is included in the non-local dial plan.

Planning Form Instructions

1.See “Numbering the System” in Chapter 2. Review the numbers available in the numbering plan you have selected. Before you begin planning remote access, to assure that TTRs are available, check the Control Unit Diagram on Form 1 to verify that one or more of the following types of modules are present: 400 LS, 400 GS/LS/TTR, 008 OPT, 800 DID (Hybrid/PBX mode only), 800 GS/LS-ID, 012 T/R, or 016 T/R modules.

2.Under the DID and Private Network Tie Trunks heading at the top of Form 3a, Incoming Trunks: Remote Access, do one of the following:

To keep the factory-set access code, check Remote Access Code: 889 and proceed to Step 3.

To change the factory-set access code:

a.Check Renumber to and write the new number on the line provided.

b.On Form 2d, System Numbering: Special Renumbers, write the new number in the Renumber to column of the Remote Access Code section at the bottom of the form. Proceed to Step 3.