MERLIN LEGEND® Communications System Release 6.1

Form 3b (Continued)

Module 3 Slot No. __________

Type of Service

Switch Type

(PRI Service Only)

Frame Format

Clock Synchronization

❑ T1 ✦*

❑ 4ESS✦*‡

❑ DEX600E

❑ D4 Compatible ✦

Priority

❑ PRI†‡

❑ 5ESS‡

❑ Legend-PBX

❑ Extended Superframe (ESF)

❑ Primary ✦

 

❑ DMS-100

❑ Legend-NTWK

 

 

Suppression (Line Code)

❑ Secondary

T1 Trunks

❑ DMS-250

 

 

 

 

 

 

❑ AMI-ZCS ✦

❑ Tertiary

 

 

 

 

 

 

Channel

For Tie/All Tie

 

❑ B8ZS

Trunk Type

S56

❑ None

Number(s) Tie-PBX

Toll

Signaling Mode

Ground-Start

 

 

 

 

Source

Loop-Start

 

 

 

 

❑ Robbed-Bit Signaling

❑ Loop ✦

Tie

 

 

 

 

(RBS) ✦

 

 

 

 

❑ Local

Unequipped

 

 

 

 

❑ Common-Channel

All Ground-

 

 

 

 

Signaling (CCS)

Activation

Start

 

 

 

 

Line Compensation

❑ Active ✦

All Loop-Start

 

 

 

 

 

 

 

 

❑ Not Active

All Tie

 

 

 

 

__________ Cable Feet

All Unequipped

 

 

 

 

❑ 1 (-.6 dB) ✦

Channel Service Unit

DID

 

 

 

 

 

 

 

 

 

❑ 2 (-1.2 dB)

❑ Foreign Exchange ✦

All DID

 

 

 

 

❑ 3 (-1.8 dB)

❑ Special Access

S56 Data

 

 

 

 

 

 

 

 

❑ 4 (-2.4 dB)

 

All S56 Data

 

 

 

 

 

 

 

 

 

 

❑ 5 (-3.0 dB)

 

NOTE: Do not configure 100D modules to do trunk-to-trunk transfers between DS1 and LS lines/trunks.

✦Factory Setting

*The factory setting of T1 is not automatically selected if you enter nothing; it must be entered.

† PRI must be selected as the Type of DS1 connectivity before PRI options are entered.

‡ AT&T Toll and 5ESS local PRI service for Release 2.0 and later requires service provider switching equipment to be either 4ESS Generic 13 through Generic 16, 5ESS Generic 6, or a 5ESS serving the FTS2000 network. PRI service on Release 1.0 or 1.1 requires a DS1 facility from a 4ESS Generic 13 through Generic 16 or 4ESS Generic 16 switch.

Form 3b-2

Page 350
Image 350
Lucent Technologies 6.1 manual Form 3b-2, Module 3 Slot No