Use these instructions if the system has a group of modems or ISDN terminal adapters.

DHGs are data calling groups that provide uniform call distribution among a group of modems or a group of ISDN terminal adapters (such as the Ascend Pipeline 25PX or 50). DHGs support the following:

Modem pools

Dedicated lines for data service

A local host computer

A workstation that functions as a gateway on a LAN

For more information, see the “Planning Overview,” earlier in this chapter. For information on modem pools, see application note, MERLIN LEGEND Communications System Modem Pooling.

Guidelines

5

Use the following guidelines for the procedure in this section:

Members of a DHG must be extension jacks of the same type: all analog or all MLX.

You can assign up to 32 DHGs or calling groups, or a combination of both types. Each DHG can have a maximum of 20 members and each data station can be a member of only one DHG.

You can designate particular lines/trunks or pools (Hybrid/PBX mode only) to ring directly into a DHG. However, incoming calls on a given line/trunk can be directed to only one DHG.

Extension numbers 770–791 and 7920–7929 are reserved automatically for calling groups and DHGs. If you want to change the extension numbers assigned to a DHG, see the information about reassigning extension numbers described in Chapter 2, “Control Unit Configuration.” The same considerations apply to data stations and voice extensions.

Forms Needed

Form 2a, System Numbering: Extension Jacks

Form 2c, System Numbering: Line/Trunk Jacks

If the system has trunk pools (Hybrid/PBX mode only) Form 2c, System Numbering: Line/Trunk Jacks

If the system includes voice calling groups, Form 7d, Group Calling

If you plan to renumber the factory-set extensions, Form 2d, System Numbering: Special Renumbers