MERLIN LEGENDCommunications System Release 6.1

Issue 1

System Planning 555-661-112

August 1998

 

 

3Lines/Trunks

Selecting Line/Trunk Options

Page 3-48

Timers

3

Timers ensure that the system takes the appropriate corrective action when the expected response is not received from the network during normal operation.

!CAUTION:

Since incorrect settings can hinder the operation of BRI facilities, consult with a Lucent Technologies representative or authorized dealer before making changes. The factory-set thresholds are standard settings and should rarely be changed.

The timers, descriptions, factory settings, and allowable thresholds are shown in

Table 3–5.

Planning Form Instructions

On Form 3i, Incoming Trunks: BRI Options (800 NI-BRI Module), under the “Timers and Counters” heading on page 2:

1.For each timer:

To keep the factory setting, check the first box under the timer name.

To change the factory setting, check the second box under the timer name and write the new threshold in the space provided.

Table 3–5. NI-1 BRI Timers

 

 

Factory

Allowable

Name

Description

Setting

Threshold

 

 

 

 

T200

The minimum time which Layer 2 must wait

1,000 ms

5005,000 ms, in

 

for an acknowledgment of a link establishment

 

increments of 500 ms

 

frame, an information frame, or a polling

 

 

 

supervisory frame, before initiating

 

 

 

retransmission procedures.

 

 

 

 

 

 

T203

The maximum time for which the Layer 2

33 seconds

10–255 seconds, in

 

link can remain inactive.

 

increments of 1 second

 

 

 

 

T303

The delay in CO response after the system

4 seconds

2–10 seconds, in

 

has sent a SETUP message to initiate an

 

increments of 1 second

 

outgoing call.

 

 

 

 

 

 

T305

The delay in response from the CO after the

30 seconds

260 seconds, in

 

system has initiated a DISConnect message

 

increments of 1 second

 

for call clearing.

 

 

 

 

 

 

T308

The delay in response from the CO after the

4 seconds

210 seconds, in

 

system has sent a RELease message for call

 

increments of 1 second

 

clearing.

 

 

If this system is installed outside of the U.S., continue to the next section.

Otherwise, skip to the following section, “Assigning Lines/Trunks.”

Page 142
Image 142
Lucent Technologies 6.1 manual Timers