MERLIN LEGENDCommunications System Release 6.1

Issue 1

System Planning 555-661-112

August 1998

1 Before You Begin

 

Requirements for Supporting CTI Applications

Page 1-8

 

 

For this configuration you must have the following equipment and software:

An Intel i386, Intel i486, or Pentium Class computer with at least

16 megabytes of RAM. Additional memory may be needed if additional applications will be running on the server machine. Refer to the MERLIN LEGEND Network Manager’s Guide form more information.

One of the following configurations:

Novell NetWare ® Version 3.12, 4.1 or 4.11

MERLIN LEGEND PassageWay Driver Version 1.1 or later installed

Telephony Services for NetWare software, Release 2.2.1 or later installed

An Eicon SCOM ISDN BRI card for the CTI link

A free 8- or 16-bit ISA slot for the ISDN BRI card

5 megabytes of disk space on the SYS (system) volume

Either Interrupt 2 or Interrupt 3 available

Microsoft Windows NT ® 4.0 Server or Windows NT 4.0 Workstation

MERLIN LEGEND NT PBX Driver Version 1.0 or later installed

CentreVu®Computer-Telephony Release 3.1 or later installed

An Eicon DIVA Version 2.0 ISDN BRI card for the CTI link

5 megabytes of disk space available

A free 16-bit ISA slot for the ISDN BRI card

System software Release 5.0 or later installed on the MERLIN LEGEND Communications System

The MERLIN LEGEND Communications System configured in Hybrid/PBX mode

An MLX port board (using firmware version 28 or later, except Version 29) installed in the MERLIN LEGEND Communications System

NOTE:

If you have Version 29, replace the board with an appropriate version, or for a replacement card, call the TSO at: 1 800 628-2888.

If the MERLIN LEGEND Communications System has only one MLX port board, you will also need System Programming and Maintenance (SPM) software, Version 5.15 or later to program your CTI link.

One port on an MLX port board is used for the link. Select from ports 2, 3, 4, 6, 7, or 8 . The CTI link port cannot be the potential operator port or the console programming port.