MERLIN LEGEND® Communications System Release 6.1
Form 3b
Incoming Trunks: DS1 Connectivity (100D Module)
Module 1 Slot No. __________
Type of Service | Switch Type | (PRI Service Only) | Frame Format | Clock Synchronization | |||
❑ T1 ✦* | ❑ 4ESS✦*‡ | ❑ DEX600E | ❑ D4 Compatible ✦ | Priority | |||
❑ PRI†‡ | ❑ 5ESS‡ | ❑ | ❑ Extended Superframe (ESF) | ||||
❑ Primary ✦ | |||||||
| ❑ | ❑ | |||||
|
| ||||||
| Suppression (Line Code) | ❑ Secondary | |||||
T1 Trunks | ❑ |
|
|
| |||
|
|
| ❑ |
| |||
|
|
|
| ❑ Tertiary | |||
|
| For Tie/All Tie |
| ||||
| Channel |
| ❑ B8ZS | ||||
Trunk Type |
| ❑ None | |||||
| Toll | S56 | |||||
Number(s) |
| ||||||
|
|
|
| Signaling Mode | Source | ||
|
|
|
| ❑ | |||
|
|
|
| ❑ Loop ✦ | |||
Tie |
|
|
|
| (RBS) ✦ | ||
|
|
|
| ❑ Local | |||
Unequipped |
|
|
|
| ❑ | ||
All Ground- |
|
|
|
| Activation | ||
|
|
|
| Signaling (CCS) | |||
Start |
|
|
|
| |||
|
|
|
|
| ❑ Active ✦ | ||
All |
|
|
|
| Line Compensation | ||
|
|
|
| ❑ Not Active | |||
All Tie |
|
|
|
| __________ Cable Feet | ||
All Unequipped |
|
|
|
| ❑ 1 | Channel Service Unit | |
DID |
|
|
|
|
| ||
|
|
|
| ❑ 2 | ❑ Foreign Exchange ✦ | ||
All DID |
|
|
|
| |||
|
|
|
| ❑ 3 | ❑ Special Access | ||
S56 Data |
|
|
|
| |||
|
|
|
| ❑ 4 |
| ||
All S56 Data |
|
|
|
|
| ||
|
|
|
|
| ❑ 5 |
| |
Module 2 Slot No. __________
Type of Service | Switch Type | (PRI Service Only) | Frame Format | Clock Synchronization | |||
❑ T1 ✦* | ❑ 4ESS✦*‡ | ❑ DEX600E | ❑ D4 Compatible ✦ | Priority | |||
❑ PRI†‡ | ❑ 5ESS‡ | ❑ | ❑ Extended Superframe (ESF) | ||||
❑ Primary ✦ | |||||||
| ❑ | ❑ |
| ||||
| Suppression (Line Code) | ❑ Secondary | |||||
T1 Trunks | ❑ |
|
|
| |||
|
|
| ❑ | ❑ Tertiary | |||
| Channel | For Tie/All Tie |
| ❑ B8ZS | |||
Trunk Type |
| ❑ None | |||||
Number(s) | Toll | S56 | Signaling Mode | ||||
|
|
|
| Source | |||
|
|
|
| ❑ | ❑ Loop ✦ | ||
Tie |
|
|
|
| (RBS) ✦ | ||
|
|
|
| ❑ Local | |||
Unequipped |
|
|
|
| ❑ | ||
|
|
|
|
| |||
All Ground- |
|
|
|
| Signaling (CCS) | Activation | |
Start |
|
|
|
| Line Compensation | ❑ Active ✦ | |
All |
|
|
|
| |||
|
|
|
| ❑ Not Active | |||
All Tie |
|
|
|
| __________ Cable Feet | ||
All Unequipped |
|
|
|
| ❑ 1 | Channel Service Unit | |
DID |
|
|
|
| ❑ 2 | ❑ Foreign Exchange ✦ | |
All DID |
|
|
|
| ❑ 3 | ❑ Special Access | |
S56 Data |
|
|
|
| |||
|
|
|
| ❑ 4 |
| ||
All S56 Data |
|
|
|
|
| ||
|
|
|
|
| ❑ 5 |
| |
NOTE: Do not configure 100D modules to do
✦Factory Setting
*The factory setting of T1 is not automatically selected if you enter nothing; it must be entered.
† PRI must be selected as the Type of DS1 connectivity before PRI options are entered.
‡ AT&T Toll and 5ESS local PRI service for Release 2.0 and later requires service provider switching equipment to be either 4ESS Generic 13 through Generic 16, 5ESS Generic 6, or a 5ESS serving the FTS2000 network. PRI service on Release 1.0 or 1.1 requires a DS1 facility from a 4ESS Generic 13 through Generic 16 or 4ESS Generic 16 switch.