MERLIN LEGENDCommunications System Release 6.1

Issue 1

System Planning 555-661-112

August 1998

H NI-1 BRI Provisioning

 

Lucent Technologies 5ESS Switch Translations

Page H-3

 

 

Fields that must be populated on Screens 4, 5, and 6:

48.

CKT TN

<enter TN>

49.

CKT LCC

<enter LCC>

50.

CKT RAX

<enter RAX value>

55.

TERMTYP

<TYPEA>

56.

DISPLAY

<Y>

60.

CSV

<1>

61.

CSV CHL

<ANY>

63.

CSV LIMIT

<1>

69.

CSD

<2>

70.

CSD CHL

<ANY>

72.

CSD LIMIT

<2>

126.

CPN SCRN

<Y>

140.

PIC

<enter PIC>

The Calling Number Identification feature is assigned using the standard BRCS preconstructed features /LICNDA and /CPCOFA. If it is possible, request /CPCPFA for the Calling Number Identification feature, as it provides a clearer display of the CPN information.

The Redirecting Number Delivery (RND) feature is assigned using the preconstructed RND feature, /RND. These features are assigned to the user in View 23.8, Field 109.

Page 489
Image 489