MERLIN LEGENDCommunications System Release 6.1

Issue 1

System Planning 555-661-112

August 1998

6 Modifications

 

Adding to the System

Page 6-4

 

 

2.On Form 1 (page 2), System Planning, review the completed Control Unit Diagram and determine whether the module type needed is present. Do one of the following:

If the module is not in the control unit, skip to Step 4.

If the module type needed is already in the control unit, proceed to Step 3.

3.Determine whether there are jacks available on the module for the new line/trunk, auxiliary equipment, or telephone by referring to Form 2a, System Numbering: Extension Jacks, or Form 2c, System Numbering: Line/Trunk Jacks. Do one of the following:

If there are sufficient jacks available on an existing module, plan to connect the added line/trunk, equipment or telephone to them. Skip to Step 6.

If no jacks are available, proceed to Step 4.

4.Plan the placement of the new module required to support the line/trunk, auxiliary equipment, or telephone by reviewing the guidelines that follow and deciding where the new module should be placed.

The power supply module must be placed in the far left slot of each carrier.

The processor module must be installed in Slot 0 of the basic carrier.

Line/trunk and/or extension modules can be placed in any order in Slots 1 through 17 (with two expansion carriers), with the following conditions:

Install the modules in each carrier from left to right, with no empty slots between modules.

If the system includes a QCC, the 008 MLX module that supports it must be the first extension module in the control unit.

Place all older 008 OPT modules (Apparatus Codes 517A28–517C28) and 012 T/R modules (Apparatus Codes from 517C13–517F13) in carriers with ring generators installed in the power supply module. Current versions of 008 OPT modules (Apparatus Code 517D28), 012 T/R modules [Apparatus Code 517G13(28)], and 016 T/R modules (Apparatus Code 517A34) have built-in ring generators and can be mixed in carriers with the older modules that already have a generator in place.