Lucent Technologies 6.1 manual T200 Timer, T203 Timer, T303 Timer, T305 Timer, T308 Timer

Models: 6.1

1 588
Download 588 pages 27.3 Kb
Page 374
Image 374

MERLIN LEGEND® Communications System Release 6.1

Form 3i (Continued)

Clock Synchronization—100D or BRI Modules*

Primary Clock

Secondary Clock

Tertiary Clock

Synchronization

Synchronization

Synchronization

Slot No. ________

Slot No. ________

Slot No. ________

DSL No. ________ (BRI

DSL No. ________ (BRI

DSL No. ________ (BRI

only)

only)

only)

Source

Source

Source

Loop

Loop

Loop

Local (100D only)

Local (100D only)

Local (100D only)

Timers

T200 Timer

1,000 ms.

_____ ms. (500 to 5,000 ms.

in increments of 500 ms)

T203 Timer

33 seconds

_____ seconds (10 to 255 seconds in increments of 1 second)

T303 Timer

4 seconds

_____ seconds (2 to 10 seconds in increments of 1 second)

T305 Timer

30 seconds

_____ seconds (2 to 60 seconds in increments of 1 second)

T308 Timer

4 seconds

_____ seconds (2 to 10 seconds in increments of 1 second)

Factory Setting

*If the system includes both 800 NI-BRI modules and 100D modules, sychronization planning should be completed at the same time. Refer to Form 3b while completing this form.