MERLIN LEGENDCommunications System Release 6.1 | Issue 1 |
System Planning | August 1998 |
3 Lines/Trunks |
|
Selecting Line/Trunk Options | Page |
|
|
NOTES:
1.Check the same signaling type used by the system to which you are connecting. For
2.Wink is the factory setting and is the preferred type, followed by Delay then Immediate. Immediate does not work with
3.Automatic incoming signaling is required if the CO switch is a Lucent Technologies 5ESS or Northern Telecom
4.
■
■
■
4.Under the E&M Signal heading, select one of the following signaling types to be used on the tie trunks:
NOTE:
E&M Signaling does not apply to digital emulated Tie trunks using T1 Switched 56 service and should not be set during administration of those trunks.
■If the tie trunks are connected to the other system through the local telephone company, check 1S (the factory setting).
■If the tie trunks are connected directly to a system that uses type 1S signaling and is located near this system, check 1C.
NOTE:
The 1C option assumes that the two systems are connected together without any provisioned facility, and without any signaling treatment equipment. When connecting a MERLIN LEGEND switch to another MERLIN LEGEND switch, use 1C on one switch and 1S on the other.