MERLIN LEGENDCommunications System Release 6.1

Issue 1

System Planning 555-661-112

August 1998

3 Lines/Trunks

 

Selecting Line/Trunk Options

Page 3-38

 

 

9.If available, assign a test telephone number that is used for maintenance by the service provider. For each 100D module with a PRI service type, write the test telephone number (up to 12 digits) used for maintenance next to the module number under the Test Telephone Numbers heading on Form 3b (page 10).

NOTE:

The factory does not assign a test telephone number. You must assign the same number as that furnished by the PRI service provider. It must be different from the numbers assigned to other channels associated with the same B-channel group.

10.Under the Timers and Counters heading, do one of the following:

To keep the factory setting, leave the Change to column blank.

To change the factory setting for any timer or counter, write the new threshold on the appropriate line in the Change to column.

11.Under the Terminal Equipment Identifier (TEI) heading, do one of the following:

To keep the factory-set TEI, check 0.

To change the factory-set TEI, write a value from 1 to 63 in the space provided.

NOTE:

If the system includes DS1 connectivity, all local offerings of DS1 configurations must be reviewed by Lucent Technologies Sales and Design Support Center (SDSC) personnel to ensure compatibility. For more information, see Appendix D, “T1/PRI Review.” Also, information required by the facilities vendor is discussed in Appendix E, DS1 Connectivity Ordering.