Lucent Technologies 6.1 manual Northern Telecom DMS-100 Switch Translations, Sonumber, Ltid

Models: 6.1

1 588
Download 588 pages 27.3 Kb
Page 505
Image 505

MERLIN LEGENDCommunications System Release 6.1

 

Issue 1

System Planning 555-661-112

 

 

August 1998

H NI-1 BRI Provisioning

 

 

 

 

Northern Telecom DMS-100

Switch Translations

 

Page H-19

 

 

 

 

 

Northern Telecom DMS-100 Switch

H

 

Translations

 

 

 

 

 

 

For the Northern Telecom DMS-100 switch, Capability Package “S” includes alternate voice/circuit-switched data on two B-channels. It also supports Calling Number Identification on data and voice connections. Please note that the assignment of two DNs is required for this package.

The DMS-100 switch also allows alternate voice and data hunting on one DN through the Multiline Hunt Group feature.

ISDN Capability Package "S"

H

The information listed below provides the DN translations that define Capability

Package “S”, and the commands that must be executed.

ISDN Ordering Code: Capability S

Provision DN1 using the following translations

Define a new Logical Terminal Identifier (LTID) using the SLT command:

SONUMBER

<<cr> or $>

LTID

<enter identifier value>

FUNCTION

<ADD>

LTCLASS

<BRAFS>

CS

<Y>

PS

<N>

MAXKEYS

<64>

TEI_TYPE

<DTEI>

ABS

<NOPMD>

ABS

<$>

EKTS

<N>

SPIDSFX option

SPID_SUFFIX <enter spid suffix value>

PVC option

VERSION <FUNCTIONAL>

ISSUE <2>

Page 505
Image 505
Lucent Technologies 6.1 manual Northern Telecom DMS-100 Switch Translations, Sonumber, Ltid, Version Functional Issue