3 Lines/Trunks

 

Selecting Line/Trunk Options

Page 3-41

 

 

If the tie trunks are connected directly to a system that uses type 5 signaling and is located near this system, check 5.

NOTE:

When connecting a MERLIN LEGEND switch to a DEFINITY switch, use the Type 5 signaling type.

5.To select dial mode:

a.Under the Inmode heading, check either the Touch-Tone column or Rotary column (factory setting) for each incoming-only and each two-way tie trunk. Use Touch-Tone for private networks.

NOTES:

1.If you have checked the Incoming or two-way column for a tie-trunk’s direction and Immediate for its incoming signaling type, you cannot use the Touch-Tone setting for Inmode.

2.Touch-Tone outmode can be used with Outtype Immediate trunks, but Touch-Tone inmode cannot be used with Intype Immediate Trunks.

b.Under the Outmode heading, check either the Touch-Tone column or the Rotary column (factory setting) for each outgoing-only and each two-way tie trunk.

6.To indicate whether the system provides a dial tone for people calling in on a tie trunk, check one of the following for each tie trunk under the Dial Tone heading:

If the system provides a dial tone, check Remote (factory setting). Use this setting for private networks.

If the system does not provide a dial tone, check Local.

7.For Answer Supv. Time, do one of the following:

To keep the factory setting, check the 300 column. Use this setting for private networks.

To change to a new value, write the new value (20 to 4800 ms) in the Other column. (Use 20-ms increments.)

8.Under the Disconnect Time heading, do one of the following:

To keep the factory setting, check the 300 column. Use this setting for private networks.

To change to a new value, write the new value (140 to 2400 ms) in the Other column. (Use 10-ms increments.)

Proceed to the next section, “DID Trunks (Hybrid/PBX Mode Only).”