MERLIN LEGEND® Communications System Release 6.1

Form 1

System Planning

Line/Trunk Capacity*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trunks

Total Trunks

 

 

Module

Number of

 

Supported

by Module

 

 

 

Type

Modules

 

by Module

Type

 

 

 

 

 

 

 

 

 

 

 

 

 

400 LS/TTR

 

x

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

800

 

x

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

408

 

x

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400 GS/LS/TTR

 

x

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

800 GS/LS

 

x

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

408 GS/LS

 

x

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

408 GS/LS-MLX

 

x

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400EM

 

x

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

800 DID

 

x

8

 

 

 

 

 

100D

 

x

24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

800 GS/LS-ID

 

x

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

800 NI-BRI**

 

x

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

System Totals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Extension Capacity*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Physical

Physical

 

 

 

Total

Module

Number of

Jacks per

Jacks by

 

Extensions

Extensions

Type

Modules

 

Module

Module Type

 

Assigned

Assigned

 

 

 

 

 

 

 

 

008 MLX

 

x

8

 

x

2

 

 

 

 

 

 

 

 

 

008 ATL

 

x

8

 

x

1

 

 

 

 

 

 

 

 

 

408

 

x

8

 

x

1

 

408 GS/LS

 

x

8

 

x

1

 

 

 

 

 

 

 

 

 

408 GS/LS-MLX

 

x

8

 

x

2

 

 

 

 

 

 

 

 

 

012

 

x

12

 

x

1

 

 

 

 

 

 

 

 

 

016

 

x

16

 

x

1

 

 

 

 

 

 

 

 

008 OPT

 

x

8

 

+ (___x4)§

 

MERLIN LEGEND Mail

N /A

x

7

N /A

x

12††

 

 

 

 

 

 

 

 

 

 

System Totals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*System capacity for Personal Directories is decreased by one whenever an MLX-20L telephone is connected to an MLX port.

Hybrid/PBX mode only.

The 100D module has one physical jack that supports 24 trunks.

§The 008 OPT module is assigned 12 extension numbers although there are only 8 physical extension jacks.

Although this MERLIN II module is supported, the 400 GS/LS/TTR, the 408 GS/LS, and the 408 GS/LS-MLX are the recommended modules.

**The 800 NI-BRI module has 8 physical jacks that support 16 trunks. Up to five 800 NI-BRI modules (or any combination of LINE/TRUNK modules up to the system maximum of 80 trunks) may be placed in the system. However, due to limitations in the 391A, 391A1, and 391A2 power supplies, the number of 800 NI-BRI modules plus 100D modules cannot exceed 3 per carrier.

††The MERLIN LEGEND Mail module has 7 dedicated internal ports, but assigns 12 total extensions.

Form 1-1

Page 319
Image 319
Lucent Technologies 6.1 manual Form, System Planning, Line/Trunk Capacity, Extension Capacity