Lucent Technologies 6.1 manual Tie Trunks Analog or Digital

Models: 6.1

1 588
Download 588 pages 27.3 Kb
Page 542
Image 542

MERLIN LEGEND R6 DESIGN IMPLEMENTATION GUIDE

(CONTINUED)

Customer Name: __________________________________

Node: ________

Public Switched Telephone Network lines:

Loop Start/Ground Start

Trk IDs

Pool

Type

COMMENTS

DID - Are DIDs connected to this system routing calls to non-local extensions? Y / N. If yes, Local DID number range _________________________ .

Non-Local DID number range _____________________ .

Are DIDs connected to another system routing calls to this system? Y / N. If yes, on what Node are the DIDs connected _______________ .

Trk IDs

Block Type

ExpDig

DelDig

AddDig

COMMENTS

Tie Trunks (Analog) or (Digital)

Trk IDs

Pool

Dir

InType

OutType

E&M Sig

InMode

OutMode

DialTone

NOTE: If analog E&M Tie Lines are used to interconnect systems, calls can only go over two hops, due to call setup time and transmission issues.

100D - DS1 (T1 - PRI)

Slot

Type

Format

Supp

Signal

LnComp

ClkSync

Src

*SwType

 

T1/PRI

D4/esf

zcs/b8zs

rbs/com

1–5

p/s/t

lp/loc

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*4E=4ESS, 5E=5ESS, 100=DMS100, 250=DMS250, DEX=DEX600E, LN=Legend-NTWK, LP=Legend-PBX

NOTE: When ordering point-to-point T1, parameters must be designated. We recommend ESF framing and B8ZS zero code suppression.

5