Lucent Technologies 6.1 manual PRI Options

Models: 6.1

1 588
Download 588 pages 27.3 Kb
Page 127
Image 127

MERLIN LEGENDCommunications System Release 6.1

Issue 1

System Planning 555-661-112

August 1998

3 Lines/Trunks

 

Selecting Line/Trunk Options

Page 3-33

 

 

9.If assigning backup synchronization:

a.In the box that describes the 100D module providing secondary synchronization, check Secondary.

b.In the box that describes the 100D module providing tertiary back up, check Tertiary.

10.Under the Source subheading in each box, do one of the following:

To retain the factory setting (that is, the system uses the clock of the far-end connection), check Loop.

To change the setting (the clock is free-running), check Local.

11.The typical setup for the primary synchronization source is Active, and other modules are set to Not Active. Under the Activation subheading in each box, do one of the following:

If loop clock synchronization is taking place, check Active (factory setting).

If the clock is free-running, check Not Active.

12.Under the Channel Service Unit heading, check Foreign Exchange.

PRI Options

If the switch is part of a private network, the PRI options are automatically set. If the switch is not part of a private network, after you have completed the module information on pages 1 and 2 of Form 3b, Incoming Trunks: DS1 Connectivity

(100D Module), use the instructions in this section to record these PRI options:

Assigning B-channels to groups

Associating outgoing and incoming services to the groups

For groups with incoming services, selecting an incoming routing method (Dial Plan Routing or Line Appearance) and providing routing information

For groups with outgoing services, completing the Network Selection, Special Services, and Call-by-Call Service tables

Identifying the trunk and telephone numbers sent to the network for caller identification

Assigning a test number used for maintenance by the service provider, changing timers and counters from the factory settings, and assigning the Terminal Equipment Identifier (TEI)

All channels assigned to a group must be on the same 100D module. Also, the order of the B-channel groups is not important. When programmed for PRI, the single DS1 jack on the 100D module supports 23 B-channels (the Channel 24 superframe transmits signaling mode information).

!CAUTION:

The order in which channels are assigned within a group must be the exact opposite of the order in which the telephone company’s switch hunts through for a channel. Consult with the service provider to determine what the correct order should be.

Page 127
Image 127
Lucent Technologies 6.1 manual PRI Options