SPECIFICATIONS | CATEGORY 5 CABLE REQUIREMENTS | |
Number of pairs | Four |
|
|
| |
Impedance | 100 ± 15% | |
|
| |
Mutual capacitance at 1 KHz | 5.6 nF per 100 m | |
|
| |
Maximum attenuation | at 4 MHz: 8.2 | |
(dB per 100 m, at 20° C) | at 31 | MHz: 11.7 |
| at 100 MHz: 22.0 | |
NEXT loss (dB minimum) | at 16 | MHz: 44 |
| at 31 | MHz: 39 |
| at 100 MHz: 32 | |
|
|
|
Twisted Pair Cables
For two devices to communicate, the transmitter of each device must be connected to the receiver of the other device. The crossover function is usually implemented internally as part of the circuitry in the device. Computers and workstation adapter cards are usually
Figure 13-1 illustrates straight-through twisted pair cable.
Figure 13-1: Straight-Through Twisted-Pair Cable
Cabling Guidelines |