Cleaning the automatic document feeder (ADF) pickup roller assembly
To clean the ADF pickup roller assembly
If your automatic document feeder (ADF) has trouble feeding paper, you can clean the ADF pickup roller assembly. To clean the assembly, use the following procedure:
1. Turn off the device and unplug the power cord.
2. Open the automatic document feeder (ADF) cover.
3.Press the round green button while lifting the green lever. Rotate the green lever until it stops in the open position. The pickup roller assembly should remain on the surface.
4.Remove the assembly, and then wipe the assembly with a soft, dry cloth.
5.Return the assembly to the same place in the ADF. The largest roller goes in back, and the gear side is away from you.
ENWW | Cleaning the automatic document feeder (ADF) pickup roller assembly 199 |