610CHAPTER 14: BULK CONFIGURATION

Figure 335 Autonegotiation Panel

The settings for each of the autonegotiation parameters will only be applied as part of the configuration template if the associated checkbox is checked. In addition, the Advertised Capabilities parameter will only be enabled if the Mode check box is checked and the Mode parameter is set to Auto.

The Autonegotiation feature places restrictions on the values which can be set for the following parameters.

Table 96 Autonegotiation Parameter Restrictions

Parameter

Restriction

 

 

Mode

The mode of operation for the port can be one of: auto,

 

10HD, 10FD, 100HD, 100FD, or 1000FD.

Advertised

The list of operational modes that the port advertises

Capabilities

during autonegotiation can be any combination of: 10HD,

 

10FD, 100HD, 100FD, 1000FD, and Flow Control.

 

 

This configuration feature panel will be considered invalid if the advertised capabilities list box is enabled, and the Flow Control option is selected, but no Full Duplex entries are selected.

Page 614
Image 614
HP Network Direr Software Products manual Autonegotiation Panel, Autonegotiation Parameter Restrictions