Q-Logic 8100 SERIES manual Deploying Npiv for VMware ESX/ESXi, Requirements for Using Npiv

Models: 8100 SERIES

1 348
Download 348 pages 63.28 Kb
Page 162
Image 162

5–Installation in a VMware Environment Deploying NPIV for VMware ESX/ESXi 4.0

Deploying NPIV for VMware ESX/ESXi 4.0

QLogic Fibre Channel and Converged Network Adapters support N_Port ID virtualization (NPIV) for Fibre Channel and FCoE SANs. NPIV enables each virtual machine to have its own Fibre Channel-FCoE WWPN by creating multiple virtual adapters on a single physical adapter. VMware ESX/ESXi 4.0 enables NPIV support on QLogic 4Gb and 8Gb Fibre Channel adapters and 8100 Series Converged Network Adapters. No additional software or hardware installation is required to support NPIV.

VMware ESX/ESXi 4.0 supports NPIV only on raw device mapping (RDM) devices. To configure NPIV, you must enable NPIV on the Fibre Channel-FCoE switch port. For information about enabling NPIV on the switch port, refer to the Fibre Channel-FCoE switch documentation. For information about NPIV, refer to the following documents:

Fibre Channel SAN Configuration Guide http://www.vmware.com/pdf/vsphere4/r40/vsp_40_san_cfg.pdf

Configuring and Troubleshooting N-Port ID Virtualization technical note (also applies to ESX 4.0) http://www.vmware.com/pdf/vi3_35_25_npiv_config.pdf

Requirements for Using NPIV

The following are required to implement NPIV:

NPIV can only be used for virtual machines with RDM disks. Virtual machines with regular virtual disks use the WWNs of the host’s physical adapters.

The physical adapters on an ESX/ESXi host, using their own WWNs, must have access to all LUNs that are to be accessed by virtual machines running on that host.

Only four WWN pairs are generated per virtual machine.

The switches must support NPIV.

The NPIV LUN number and NPIV target ID must match the physical LUN and Target ID when configuring an NPIV LUN for access at the storage level.

Always use the vSphere client to manage virtual machines with WWNs.

The virtual machine must be powered off to configure it for NPIV.