7–Configuring FCoE in a Windows Environment Boot from SAN

If failover capabilities are required during boot-from-SAN, multiple QLogic 8100 Series Adapters are required to create redundant paths to the boot device. Consult the server manufacturer’s documentation to determine the maximum number of QLogic 8100 Series Adapters that the server can support.

Converged Network Adapter Requirements

The Converged Network Adapter must meet the following requirements:

QLogic 8100 Series Adapter with current firmware.

QLogic 8100 Series Adapter with the boot BIOS is enabled. Typically, the boot BIOS is disabled by default. Disregard this requirement if a UEFI-enabled server is used.

If failover capabilities are required during boot-from-SAN, multiple QLogic 8100 Series Adapters are required to create redundant paths to the boot device.

Record the WWPN and WWNN for each adapter prior to installation. The WWPN and WWNN can be found on a label on the adapter.

FCoE Switch Requirements

Ensure that the FCoE switch has the correct zoning configuration according to the following rules:

Locate the FCoE switch on the SAN that contains the boot LUN so that the FCoE switch is visible to the server through the QLogic adapter.

The host must have exclusive access to the LUN from which it boots. No other host on the SAN should be able to detect or access the same logical disk.

Only one instance of the boot LUN can be visible to the server during the initial installation. The installation may fail if multiple instances of the boot LUN are available to the server through different paths or through the same LUN presented through two different storage array controllers. If failover is required, configure boot-from-SAN after the initial installation is complete.

Limit zones to no more than one adapter port to avoid RSCN interruptions from other hosts in the fabric.

Storage Array Requirements

Some storage arrays cannot support boot-from-SAN for specific environments. Consult the storage array manufacturer’s documentation to confirm that the array and the firmware support boot-from-SAN. Consider the storage array and any limitations regarding boot-from-SAN.

Create and present an appropriately sized LUN to the QLogic 8100 Series Adapter port.

7-16

FE0254601-00 A

Page 244
Image 244
Q-Logic 8100 SERIES manual Converged Network Adapter Requirements, FCoE Switch Requirements, Storage Array Requirements