6–Configuring NIC Functionality in the Converged Network Adapter Configuring the NIC in a Linux Environment

b.Open the VLAN interface network configuration script with an editor, and make the following changes:

Replace the string DEVICE=eth0 with DEVICE=eth0.5.

Append the string VLAN=yes to the end of the file.

Figure 6-36shows the resulting file.

Figure 6-36. Creating a Network Configuration File—VLAN Interface

c. Save the file, and then exit the editor.

2.Restart the network services by issuing the following command:

# service network restart

Verify the VLAN configuration

To verify if the VLAN interface (ethX.VLAN ID or bondX.VLAN ID)

1.Examine the VLAN network interface using the /proc interface. For example:

# cat /proc/net/bonding/bond0

Figure 6-37shows that eth0 is the physical interface and the VLAN interface is eth0.5.

Figure 6-37. Verify the VLAN Interface

FE0254601-00 A