Specifications

Range

• 0.3 m (1 ft) to 15 m (50 ft), dependent on transducer

Accuracy

• 0.25% of maximum range or 6 mm (0.24”), whichever is greater

Resolution

• 0.1% of program range1 or 2 mm (0.08”), whichever is greater

Memory

1 MB static RAM with battery backup

512 kB flash EPROM

Programming

Primary

• handheld programmer

Secondary

PC running SIMATIC PDM

PC running Dolphin Plus software

Display

• back lit LCD

Temperature Compensation

• Range: -50 to 150 °C (-58 to 302 °F)

Source

integral transducer sensor

TS-3 temperature sensor

programmable fixed temperature

Temperature Error

Sensor

• 0.09 % of range

1.Program range is defined as the empty distance from the face of the transducer (P006) plus any range extension (P801).