P908 Scanner

Press ENTER to cycle the scanner relay while firing the transmitter.

Use this parameter to ensure that both transducers are being stimulated.

P910 Toggle Relays

Used to energize and de-energize relays directly.

Primary Index

Global

 

 

Values

0 to 6

 

 

 

Related

P119 mA Relay Logic Test

 

 

 

Enter the relay number and then toggle between energized and de-energized, as required. Enter 0 to toggle all relays at once.

Applies only to relays with P119 = 0 (algorithm control). Use this parameter to confirm that relay contacts are opening and closing.

This feature is helpful when P119 does not give expected results even though programming was verified.

P911 mA Output Value

Access this parameter to display the current value of the mA output.

Primary Index

mA output

 

 

Values

Range: 0.10 to 25.00

 

 

 

Related

P200 mA Output Range

P201 mA Output Function

 

 

 

 

Additionally, this feature may be used to enter a desired value. The mA output immediately assumes the value entered regardless of any restrictions programmed.

P912 Transducer Temperature

Use this feature to display the temperature in °C (as monitored by the connected transducer).

Primary Index

Transducer

 

 

Values

Range: -50 to 150

 

 

Err is displayed if the transducer is not equipped with an internal temperature sensor.