Siemens 200 instruction manual Example Exponents, PMD Type Exponent sample only

Models: 200

1 282
Download 282 pages 42.81 Kb
Page 177
Image 177

Example Exponents

PMD Type

Exponent (sample only)

Suppressed Rectangular Weir

1.50

Cipolletti Weir

1.50

Venturi Flume

1.50

Parshall Flume

1.22 to 1.607

Leopold Lagco

1.547

V-Notch Weir

2.50

 

 

P602 Primary Measuring Device Dimensions [MR 200]

The dimensions of the Primary Measuring Device (PMD).

Primary Index

 

Single Point Model

Dual Point Model

 

 

 

Global

Transducer and Dimension

 

 

 

 

Secondary Index

Dimension

 

 

 

 

 

ISO 1438/1

 

 

 

 

 

 

1

Notch Angle

 

 

 

 

 

 

2

Discharge Coefficient

 

 

 

 

 

 

ISO 4359

 

 

 

 

 

 

1

Approach width

 

 

 

 

 

 

2

Throat width

 

 

 

 

 

Index Values for

3

Hump Height

 

 

 

 

Supported PMDs

4

Throat Length

 

 

 

 

 

 

 

 

5

Velocity coefficient

 

 

 

 

 

 

6

Discharge coefficient

 

 

 

 

 

 

Palmer Bowlus

 

 

 

 

 

 

1

Flume width

 

 

 

 

 

 

H Flume

 

 

 

 

 

 

1

Flume height

 

 

 

 

 

Altered By

P600 Primary Measuring Device

 

 

 

 

Use this parameter if the Primary Measuring Device is directly supported (P600=2,3,6,7). The dimensions required for each PMD vary.

For more information on PMD, see page 73.

7ML19981FB06

MultiRanger 100/200 – INSTRUCTION MANUAL

Page 167

Parameters

Page 177
Image 177
Siemens 200 Example Exponents, PMD Type Exponent sample only, Dimensions of the Primary Measuring Device PMD