Operation

Activating the MultiRanger

All the instructions in the following procedures apply to the hand programmer and assume that the MultiRanger is activated.

1.Power the MultiRanger.

2.Point the programmer at the unit and press PROGRAM .

3.Press DISPLAY .

Note: Power up display

Single Point Model

preset to display distance from the face of the transducer to the material

transducer selection is preset for the XPS-10

empty distance is preset to 5 m

Dual Point Model

starts in an OFF state and does not take level measurements

to set up measurement, the quick start parameters must be configured

See Quick Start parameters on page 119

Changing Parameters

Note: If Parameter Value alteration is not permitted, access the Lock parameter (P000) and enter the security code, (see Security below).

1.Starting in RUN mode, press PROGRAM and then press DISPLAY to put the unit into PROGRAM mode.

2.Press DISPLAY to select the Parameter Number field.

3.Enter the Parameter Number (e.g. 110). After the third digit is entered, the parameter value is shown.

4.Enter the new value, and press ENTER . The MultiRanger interprets the value, either accepting or replacing it with a valid value.

Helpful Hints

For parameters P001 to P009, press a single digit (1–9) and then press DISPLAY to show that parameter.

The ? icon indicates that the MultiRanger has accepted the value but that it conflicts with other values entered. Double-check your programming.

By default, the SCROLL arrows show only the Quick Start parameters and any that have been changed.

P733 sets all parameters to be scroll-accessed.

Page 32

MultiRanger 100/200 – INSTRUCTION MANUAL

7ML19981FB06