Parameters

P913 Sensor Temperature

Access this parameter to display the temperature in °C (as monitored by the TS-3).

Primary Index

Global

 

 

Values

Range: -50 to 150

 

 

OPEn is displayed if a TS-3 is not connected.

P914 mA Input [MR 200]

Use this feature to display the mA input value (in mA).

Primary Index

mA input

 

 

Values

Range: 0.000 to 24.00

 

 

Measurement (P920 to P927)

All of these parameters are available in RUN mode and used to verify programming. See Readings in RUN Mode on page 23.

The range and values shown for each of these parameters depends on the Operation (P001) chosen. The readings for each operation are listed below.

To Access in RUN Mode

1.Ensure the device is in RUN mode.

2. Press P .The Auxiliary Reading field becomes underscores P_ _ _

3.Type the parameter number. The field changes to the value of the specified parameter.

These parameters are also available in simulation mode. See the Testing the Configuration section page 85 for instructions on how to control the simulation direction and rate.

P920 Reading Measurement

Corresponds to the final reading after all programming is applied.

Please note that the following features apply only to the MultiRanger 200: Difference, Average, OCM, and Pump Totalizer.

Primary Index

Level

 

 

Values

Range: -999 to 9999

 

 

In general this means that: P920 = (Reading x P061) + P062.

Page 218

MultiRanger 100/200 – INSTRUCTION MANUAL

7ML19981FB06

Page 228
Image 228