Multiranger
Manual for agreement with
Technical data subject to change
This document is available in bound version
Instrumentation described, variations
Table of Contents
Dolphin Plus Toolbar Buttons
Iii
Set Relays to First in First OUT Fifo Assist MR
Starting Pumps by Rate of Level Change MR
Open Channel Monitoring OCM
100
Communication Appendix a Single Parameter Access SPA
Vii
Set the MultiRanger to Ignore the Bad Echo
Connecting a transducer with RG62 coaxial extension cable
Viii
Coaxial Transducer Extention
MultiRanger
MultiRanger 100
Manual
MultiRanger 100/200
Manual Symbols
Configuration Examples
Specifications
Specifications
Power
Mounting
Temperature Error
Resolution
Temperature Compensation
Accuracy
Outputs
Enclosure
Weight
Inputs
Approvals
Cable
Maximum
Mounting Locations
Installation
Mounting
Recommended
Wall Mount
Enclosure Dimensions
Mounting Instructions
Mounting the Enclosure
Unscrew the glands and attach them loosely to the enclosure
Cable routed through a conduit
Cable exposed and entering through the cable glands
Tighten the glands to form a good seal
Cutout Dimensions
Panel Mount
Cutout Instructions
Panel Mount Dimensions
Mounting the Enclosure
Helpful hint
Open the enclosure lid
Installing the Battery
MultiRanger Board
Close and secure enclosure lid
Installing SmartLinx Card
Wiring
Wiring
MultiRanger
Please do not overtighten the screws
Terminal Board
Cables
Connection Cable Type
Relays
Power Failure
Transducers
Relay Ratings
MA Output
Temperature Sensor
MA Input MR 200 only
Sensor only. Leave
Power
Level System Synchronization
Digital Communications
RS-232 Serial Connection
RS-485 Serial Connection
Discrete Inputs
Operating the MultiRanger
RUN Mode
RUN Mode
Operation
Icon Index Type
Readings in RUN Mode
Icons indicating index type Item 1 edited in Program mode
Operation Key
Status Parameters
Values
Auxiliary Reading
Adjusting the primary reading for four-digit LCD readout
Controlling the Display
Action
Parameter Index Value Description
Setting the Default Auxiliary Reading
Multiple Readings MR 200 only
Changing Number Scrolling Speed
Hand Programmer
Program Mode
Starting Program Mode
To activate Program from RUN mode, press Program and then
Operation Keys Programming Mode
Programmer Keys
Digit Totalizer toggle MR 200 only
Dolphin Plus
Compatible with product software versions 1.06 and earlier1
Dolphin Plus Toolbar Buttons
Button Action
Compatible with product software versions 1.07 and later1
Simatic Process Device Manager PDM
Device Description
See P900 for Software Revision Number 7ML19981FB06
Activating the MultiRanger
Changing Parameters
Helpful Hints
Parameters Types
Using Units or Percent %
Security
Maximum
Master Reset P999
Parameter Reset
Default Values
Display Readout
Changing ParametersDolphin Plus
MultiRanger Display
Accessing a Parameter Index
Parameter Indexing
Index Number
Primary and Secondary Indexes
Accessing a Secondary Index
Example Setting P1113 =
Primary Index
Example MR 200 only
Starting Measurement
Single Point Models
Parameter
Operation Index Description
Dual Point Models
Average or Differential MR 200 only
Index Value Description
Response Rate
Dimensions MR 200 only
Measurement Conditions
Failsafe
General Introduction
Alarm
Relays
Relay Function
Pump
Miscellaneous
Relay Status Non Run Modes
Relay States
Relay Related Parameters
Relay Types
Relay Wiring Test
Relay Activation
HOLd Keeps the relay in the current state
Relay Failsafe
Relay Logic is Modified
Energizes the relay
Preset Applications
Value Parameters Affected
Backup Level Override
Backup Level Override Parameters
Backup Level Override
Wiring the Discrete Inputs
Discrete Inputs
Programming the Discrete Input Logic
Level Reading Parameters
MA I/O
MA Input MR
MA I/O
Calibrating 20 mA Output
MA LI/O
Calibrating 4 mA Output
Verifying the mA Range
Volume
Volume MR
Tank Shape and Dimensions
Readings
P051
Characterization Chart MR
Example Chart
Level P054
MultiRanger 200 only
Which the volumes are known
Determines the volumes which
All level readings
Level
Alarms
Alarms
Set the Common Parameters
Setting a Filling Rate Alarm
Setting Simple Level Alarms
Alarm Designation
Rate MR
Bounds/ Out of Bounds Range MR
Cable Fault
Temperature MR
Parameter Index Value
This shows a high alarm
Loss of Echo LOE
Pump Control
Setting a Pump Down Group
Setting a group of three pumps to pump down a wet well
Example Sewage Wet Well
Setting a Pump Up Reservoir Group
Set Relays to Alternate Duty Assist
Set the on Setpoints
Sample values
3m By using index 0 all six relays are set at
Set the Relay OFF Setpoints
4m Sets the three setpoints for the pump relays
Set the Relay on Setpoints MR
Other Pump Control Algorithms
Set Relays to Fixed Duty Assist
Set the Relay OFF Setpoints MR
Fixed Duty BACKUP. Only one pump will
Set Relays to Fixed Duty Backup MR
Set Relays to Alternate Duty Service MR
Ever run at one time
Pump Control Parameter
Optional Pump Controls
Starting Pumps by Rate of Level Change MR
P112 P113 P121 P132
Rotating Pumps by Service Ratio MR
Single and Dual Point MR
Time
Totalizing Pumped Volume MR
Setting Independent Failsafe Controls
Set in RUN Mode
Setting a Pump to Run On MR
Setting the Pump Start Delays MR
Reducing Wall Cling MR
Groups Pumps One and Two
Setting a Flush Valve MR
Grouping Pumps MR
Groups Pumps Three and Four
Information Available Parameter Access
Tracking Pump Usage
Relay Controlled by Communications
Setting a Rake Control
Rake Screen Control MR
Point Three Level Distance = h1 -h2
Set Relay 1 Operate Rake
Setting the Common Parameters
Set Relays 2 to 4 Level Alarms
Screen Control
Totalizer
External Totalizers and Flow Samplers MR
Relay Contacts
Counter Formula
Source of units depends on the operation
Based on Volume and Time
Flow Sampler
Operation Units Source Parameter
Common Parameters
Dimensional P600 = 2,3,6,7
Open Channel Monitoring OCM MR
Exponential P600 =
Examples on the following pages show both methods
Setting Zero Head
Channel Monitoring
P603 P006 P007 P605
Setting Totalized Volume
Applications Supported by MultiRanger
BS-3680 / ISO 1438/1 Thin plate V notch weir
P600 P602
BS-3680 / ISO 4359 Rectangular Flume
Plan View 4 to 5 x hmax hmax = P007
P605 P608
Palmer Bowlus Flume
Application Information
Flume
Flume
Flume Size Diameter in feet Point of Measurement Cminches
Flume height D
P600 Exponential Function P601
Applicable Weir Profiles
Standard Weirs
Weir Profile
Sized by throat width Set on solid foundation
Non-Applicable Weir Profiles
Parshall Flume
Transducer P006
Maximum Head preset P007
Leopold Lagco Flume
Leopold Lagco Flume
Cut Throat Flume
Cut Throat Flume
P611 Linear Flow Curved Head P610
Universal Calculation Support
Typical Flow Characterization
Zero Flow
Trapezoidal Dual Range nested Parshall
Example Flumes
Example Weirs
These weirs could require universal calculation
Simulation
Testing the Configuration
Testing the Configuration
Simulating a Single Measurement
Press
Checking Volume Characterization MR
Checking OCM Flow Characterization MR
No effect
Checkout
Application Test
Testing the Configuration
Optional SmartLinxCards
MultiRanger Communications
MultiRanger Communication Systems
Communications
Modbus
Communication Systems
Communication Ports
Port Connection Location Interface
P770 Dolphin P772
SmartLinx
P770 Modbus RTU slave P771
Data rate of 115.2 Kilo baud
Comms Installation
Communications Installation
Wiring Guidelines
Ports 1
Port 2 RS-485
To connect the unit to a modem using an RS-232 jack
Port 1 RS-232 RJ-11 Jack
Computer DB-9 male RJ-11 to DB 9 converter
P770 Port Protocol
Configuring Communication Ports Parameters
To connect the unit to a modem using an RS-485 port
P771 Network Address
P774 Data Bits
P772 Baud Rate
P773 Parity
P775 Stop Bits
P782 Parameter Index Location
P779 Modem Inactivity Timeout
P778 Modem Available
Hanging Up
Type Description Start Data Type Read
Modbus Register Map
Register Map for Most Common Data
Modbus Register Types
Word Order R40,062
Map ID R40,063
Modbus Register Types Description Start
Totalizer R41,040 R41,043
Product ID R40,064
Point Data R41,010 R41,031
Input/Output R41,070 R41,143
MA Input R41,090 MR
Discrete Inputs R41,070
Relay Outputs R41,080
MA Output R41,110-41,111
Pump Hours R41,450 R41,461
Pumped Volume R41,440 R41,443 MR
Pump OFF Setpoint R41,430 R41,435
Pump Starts R41,470 R41,475
Format Register # Parameter #
Parameter Access R43,998 R46,999
Indexing the Parameter Access Area
Usually, the parameters are all read / write
Parameter Specific Index Method P782 =
Reading Parameters
Global Index Method P782 =
Examples are
Writing Parameters
Parameter-Specific Index Method P782 =
Format Words R46,000 to R46,999
Global Index Method P782 =
Format Registers
Decimal Offset Example
Format
Decimal
Bit Values
Data Types
Numeric Values
Unsigned Double Precision Integer UINT32
One example is P807, Transducer Noise, where
Yy = value % 256 128 where % is the modulus operator
Split Values
Two registers are read as a 32-bit integer
Text Messages
Number Text Message as displayed on LCD
Relay Function Codes P111 Only
MultiRanger
Control Relay Function Code Number P111
Error Handling
Error Handling
Error Handling
Modbus Responses
Error Handling
Communication Troubleshooting
Generally
Specifically
Communication Appendix a
Mapping
Reading Parameters
Address Description
Writing Parameters
Format Register
Bits Values Description
Error Codes
Currently the MultiRanger has two error codes available
Helpful Hints
Parameter Reference
MultiRanger 100 and MultiRanger
Parameters
Transducer2
Index types
# of indexes
Up to 7 2
P001 Operation
Quick Start P001 to P007
P000 Lock
Single Point Model Dual Point Model
Single Point Model Use
P002 Material
For DPD and DPA Programming MR
Dual Point Model Use
P003 Maximum Process Speed
P004 Transducer
Determines level change reaction
Specifies measurement units used for dimensional values
P005 Units
P006 Empty
Volume P050 to P055 MR
P007 Span
Sets the range levels to be measured
P050 Tank Shape MR
Volume calculation not required
Preset Flat Level Bottom
Parabola Bottom
P051 Maximum Volume MR
Examples
P054 Level Breakpoints Universal Volume Calculation MR
P052 Tank Dimension a MR
P053 Tank Dimension L MR
Entering a Level Breakpoint
Display and Reading P060 to P062
Typical volume calculations
Entering a Volume Breakpoint
P060 Decimal Position
P607 Flowrate Decimal
P061 Convert Reading MR
P062 Offset Reading
Range -999 to
Backup Level Override
P064 Reading Override Enable
P065 Reading Override Value
P066 Override Time Delay
P069 Password
Failsafe P070 to P072
P070 Failsafe Timer
Material level reported when a Failsafe State is initiated
P071 Failsafe Material Level
Relays P100 to P119
P072 Failsafe Level Advance
Control Functions P111
P100 Preset Applications MR
Six preset applications to configure or bench test the unit
Setpoints P112, P113
P110 Level Source
Single Point Mode standard
Dual Point Mode optional
P111 Relay Control Function
Values For P111 Control Type Relay Control
P112 Relay on Setpoint
P115 Relay Interval Setpoint MR
Distance above and below the bound alarm setpoints
P113 Relay OFF Setpoint
P116 Dead Band MR
P118 Relay Output Logic
Value Logic Alarm
Power Failure
Relay States
P121 Pump by Rate MR
P118 is preset to 2 which is positive logic
P119 Relay Logic Test
Positive Logic
P129 Relay Failsafe
P122 Pump Service Ratio MR
Independent Relay Failsafe P129
This parameter only relates to relays with P111 = 54 or
P130 Pump Run-On Interval MR
Relay Function P111 Preset P129
Advanced Pump Control Modifiers P130 to P137 MR
To select an independent Relay Failsafe value
Sets the minimum delay in seconds between pump starts
P132 Pump Start Delay MR
P133 Pump Power Resumption Delay MR
P131 Pump Run-On Duration MR
P136 Wall Cling Reduction MR
P137 Pump Group MR
Flush Systems P170 to P173 MR
Single Point Mode
Dual Point Mode
P170 Flush Pump MR
P173 Flush Duration MR
P171 Flush Cycles MR
P172 Flush Interval MR
Sets the number of pump cycles requiring flush control
P201 mA Output Function
MA Output P200 to P219
P200 mA Output Range
Determines the mA output range
P202 mA Output Allocation
P203 mA Output Value / Transducer
Displays current mA output value for the Point Number
MA Output Limits P212 and P213
P201-mA Function Action Settings
Independent mA Setpoints P210 and P211
P210 0/4 mA Output Setpoint
P213 mA Output Max Limit
MA Output Trim P214 to P215
P212 mA Output Min Limit
P214 4 mA Output Trim
P215 20 mA Output Trim
MA Output Failsafe P219 MR
MA Input P250 to P260 MR
P219 mA Output Failsafe MR
P252 20 mA Input Level MR
P250 mA Input Range MR
P251 0 or 4 mA Input Level MR
Shows the mA input range of the connected mA device
P254 Scaled mA Input Value MR
Discrete Input Functions P270 to P275
P253 Input Filter Time Constant MR
P260 mA Raw Input MR
P270 Discrete Input Function
Record Temperatures P300 to P303
Standard Data Logging P300 to P321
P275 Scaled Discrete Input Value
P300 Temperature, Transducer Maximum
P301 Temperature, Transducer Minimum
P302 Temperature, Sensor Maximum
Pump Records P309 to P312
P303 Temperature, Sensor Minimum
Record Readings P304 and P305
P304 Reading Max
P311 Pump Starts
P309 Pump RUN Time
P310 Pump Hours
P312 Pump Run Ons MR
P320 Flow Max MR
Flow Records P320 and P321 MR
LCD Totalizer P322 and P323 MR
P321 Flow Min MR
Profile Records P330 to P337
P322 LCD Total Low MR
P323 LCD Total High MR
P330 Profile Record
Code Description
P332 Auto Record Transducer
P331 Auto Record Enable
Use to enable/disable the Auto Profile Record function
P333 Auto Record Interval
Auto Record on and OFF Setpoints P334 to P337
P334 Auto Record on Setpoint
P335 Auto Record OFF Setpoint
P336 Auto Record Filling / Emptying
P337 Auto Record LOE Time
P341 RUN Time
Installation Records P340 to P342
P340 Date of Manufacture
P342 Start Ups
Single Point Model Dual
Open Channel Monitoring P600 to P621 MR
P600 Primary Measuring Device MR
Type of primary measuring device PMD used
P601 Flow Exponent MR
Word on Exponents
Exponent for the flow calculation formula
Dimensions of the Primary Measuring Device PMD
Example Exponents
PMD Type Exponent sample only
Level value associated with Maximum Flow, in Units P005
P603 Maximum Head MR
P604 Maximum Flow MR
Maximum flowrate associated with Maximum Head P603
P605 Zero Head MR
Conditions Enter
P606 Time Units MR
P607 Flowrate Decimal MR
Maximum number of decimal places to be displayed
Cubic metres / hour Cubic metres / day Cubic feet / second
Volume units used to display total flow
P608 Flowrate Units MR
Million gallons / day Imperial
Head vs. Flowrate P610 and P611
P610 Head Breakpoints MR
P611 Breakpoint Flowrates MR
Flowrate corresponding to each Head Breakpoint entered
P621 Auto Zero Head MR
Procedure, with head steady
P620 Low Flow Cutoff MR
Calibrates Zero Head P605 based on actual head measurements
Pumped Volume Totalizer P622 MR
P622 Inflow / Discharge Adjust MR
Or discharge
Totalizer features apply to MultiRanger 200 only
Totalizer P630 to P645 MR
P630 LCD Totalized Multiplier MR
Enter the maximum number of decimal places to be displayed
P633 LCD Totalized Decimal Position MR
P640 Remote Totalized Multiplier MR
100 1000
P641 Flow Sampler Mantissa MR
P642 Flow Sampler Exponent MR
Enter the mantissa Y for the exponent Z in the formula
P645 Relay Duration MR
Offset Adjusts the measurements by a fixed amount
Range Calibration P650 to P654
Enter the exponent Z for the mantissa Y in the formula
P651 Sound Velocity Calibration
Condition for use of this feature
P650 Offset Calibration
Offset Calibration
P652 Offset Correction
Using Sound Velocity Calibration
Value altered when an Offset Calibration is performed
P653 Velocity
Temperature Compensation P660 to P664
P654 Velocity at 20C
P660 Temp Source
P661 Temp Fixed
P663 Temperature Transducer Allocation
Range -199 to 199 preset = 20 C
P660 Temp Source
Rate P700 to P708
P664 Temperature
View the transducer temperature in C
P700 Max Fill Rate
P701 Max Empty Rate
P702 Filling Indicator
Fill rate required to activate the LCD Filling indicator
P003 Value Meters / Minute
P704 Rate Filter
P703 Emptying Indicator
Empty rate required to activate the LCD Emptying indicator
Damps Rate Value P707 fluctuations
P707 Rate Value
P705 Rate Update Time
P706 Rate Update Distance
P005 Units P007 Span
Measurement Verification P710 to P713
P708 Volume Rate Display MR
Press Reading to toggle between percent and volume
P710 Fuzz Filter
P711 Echo Lock
Global Transducer Off
P713 Echo Lock Window P820 Algorithm
P712 Echo Lock Sampling
P711 value P712 preset value
Adjusts the size of the Echo Lock Window
P713 Echo Lock Window
Transducer Scanning P726 to P729
P727 Scan Delay
Enables the System Sync on the terminal block
P726 Level System Sync
P729 Scan Time
P728 Shot Delay
Display P730 to P739
P730 Auxiliary Reading
Adjusts the Point Number display scroll speed
P732 Display Delay
P733 Scroll Access
P731 Auxiliary Reading Key
P737 Primary Reading MR
P741 Communications Timeout
P735 Backlight
Controls the LCD backlighting
P770 Port Protocol
SmartLinx Reserved P750 to P769
Communications P770 to P782
P771 Network Address
P772 Baud Rate
P773 Parity
P774 Data Bits
P779 Modem Inactivity Timeout
P775 Stop Bits
P778 Modem Available
P782 Parameter Index Location
SmartLinx Hardware Testing P790 to P795
P790 Hardware Error
Global
P791 Hardware Error Code
P792 Hardware Error Count
P794 SmartLinx Module Type P795 SmartLinx Protocol
P800 Near Blanking
Echo Processing P800 to P807
P799 Communications Control
Space near the transducer face which cannot be measured
P801 Range Extension
P802 Transducer with Submergence Shield
Determines what type of ultrasonic shots are fired
P803 Shot / Pulse Mode
P804 Confidence Threshold
Determines which echoes are evaluated by software
P807 Noise
P805 Echo Confidence
P806 Echo Strength
Display Description
P816 Echo Time Raw
Advanced Echo Processing P815 to P825
P815 Echo Time Filtered
Time in ms from the transmit pulse to the processed echo
P820 Algorithm
Dampens spikes in the echo profile to reduce false readings
P821 Spike Filter
P822 Narrow Echo Filter
Filters out echoes of a specific width
P823 Reform Echo
P825 Echo Marker Trigger
Smoothes jagged peaks in the echo profile
P831 TVT Shaper
Advanced TVT Adjustment P830 to P835
P830 TVT Type
Selects the TVT Curve used
P832 TVT Shaper Adjust
P833 TVT Start Min
P834 TVT Start Duration
P835 TVT Slope Min
P833 TVT Start Min P835 TVT Slope Min
Display before Auto False Echo Suppression Or when P837 =
P837 Auto False-Echo Suppression
Values
P839 TVT Hover Level
Set Up
P838 Auto False-Echo Suppression Distance
Display after Auto False Echo Suppression
Advanced Shot Adjustment P840 to P852
P840 Short Shot Number
P841 Long Shot Number
P842 Short Shot Frequency
P843 Long Shot Frequency
P844 Short Shot Width
P845 Long Shot Width
Adjust the width in ms of the long shot transmit pulse
Range 30 to Preset P840 Short Shot Number
P850 Short Shot Bias
P900 Software Revision Number
Test P900 to P913
P852 Short Shot Range
P901 Memory
P904 Keypad
P902 Watchdog
P903 Display
P905 Transmit Pulse
P910 Toggle Relays
P912 Transducer Temperature
P908 Scanner
P911 mA Output Value
Measurement P920 to P927
P913 Sensor Temperature
To Access in RUN Mode
P914 mA Input MR
P923 Distance Measurement
P921 Material Measurement
P922 Space Measurement
P001 P050 = P050 ≠
P926 Head Measurement MR
P924 Volume Measurement MR
P925 Flow Measurement MR
Calculated flowrate in Max Flow P604 units or % of Max Flow
P927 Distance Measurement
Master Reset P999
This feature resets all parameters to original values
Pressing the Clear keys 7ML19981FB06
Parameters
Appendix a Index Types
Global View only Breakpoint
Parameter depen Dent up to 7 2 Or 3
Dolphin Plus Display
Transmit Pulse
Echo Processing
Cursor
TVT Time Varying Threshold curves
Auto False-Echo Suppression
Distance Calculation
Sound Velocity
MultiRanger 100/200
Volume Calculation MR
Scanning
Universal, Linear P050 =
Flow Calculation
Universal, Curved MR
Set P050 =
Universal, Linear MR
See also Typical Flow Characterization on
Values Dependent on Maximum Process
Maximum Process Speed
Parameter Units
Fast
Appendix C Troubleshooting
Common Problems Chart
Symptom Cause Action
Removed + removed Go to
Noise Problems
Determine the Noise Source
Acoustical Noise
Reducing Electrical Noise
Common Wiring Problems
Non-Transducer Noise Sources
Reducing Acoustical Noise
Adjust Transducer Aiming
Measurement Difficulties
Flashing LOE Display
Fixed Reading
Obstructions in the Sound Beam
Nozzle Mountings
Set the MultiRanger to Ignore the Bad Echo
Adjust the Echo Algorithm
Wrong Reading
Types of Wrong Readings
Poor Ring Down
Transducer Ringing
Normal Ring Down
Ring Down TVT curve
Unit Repair and Excluded Liability
Pump Groups
Pump Control Options
Pump Control Algorithms
Pump by Rate MR
Fixed Duty Backup P111 = 51 MR
Fixed Duty Assist P111 =
Index Relays
Alternate Duty Backup P111 = 53 MR
Alternate Duty Assist P111 =
Cycle Relays
Service Ratio Duty Assist P111 = 54 MR
Relay Operation for P118 = 2 MR
First In First Out Fifo P111 = 56 MR
Service Ratio Duty Backup P111 = 55 MR
Other Pump Controls MR
Pump by Rate P121 MR
Flush Device P170 to P173
Appendix E Updating Software
Updating Software
Mounting a MultiRanger 100/200
Connecting the Transducer
Appendix F Upgrading
Coaxial Transducer Extention
Connecting a transducer with RG62 coaxial extension cable
Existing installation
Relay Parameter Value
Alarm
MultiRanger Plus
On setpoint
Appendix G Conduit Entry for Class 1, Div 2 Applications
Appendix G
7ML19981FBO6
23650314
MultiRanger
Soft
Changes
Soft Ware Date Changes Rev
Simatic PDM related TVT display
Systems testing
Property no Reset
Improvement to prevent it from going
Using Dolphin+
Eliminated rogue watchdog resets when
Improved Preset Application values
Changed P132 to global
Now being protected from other units’ Transmit pulse
OCM Time Units improvement
From Modbus map reg
DDs required 7ML19981FB06
Volume
Property noReset
Improved volume calculation for 3rd point
Reading some floats as decimal shifted
Programming Charts
Parameter Charts
P000 Lock G
P116 Deadband P118 Relay Output Logic P119 Relay Logic Test
P121 Pump by Rate MR P122 Pump Service Ratio MR
P113 Relay OFF Setpoint P115
P210 0/4 mA Output Setpoint P211 20 mA Output Setpoint
P320 Flow Max MR P321 Flow Min MR
P219 mA Output FailsafeMR
P304 Reading Max P305 Reading Min
P322 LCD Total Low MR P323 LCD Total High MR
P340 Date of Manufacture P341 RUN Time P342 Start Ups
Open Channel Monitoring
Temperature Compensation
P737 Primary Reading MR P741 Communications Timeout
SmartLinx Reserved Communications
Reserved
Parameter
Index
153
Parameter access
105
103
207
203
212
162
110
Service ratio
Testing
242
167
Characterization chart
Weir
233
Page
Page
7ml19981FB06