Reading Measurements by Operation

 

 

 

 

 

 

P001

P050 = 0

P050 0

 

 

 

 

 

0

– OFF

- - - -

- - - -

 

 

 

 

 

1

– Level

P921

P924

 

 

 

 

 

2

– Space

P922

100% - P924

 

 

 

 

 

3

– Distance

P927

P927

 

 

 

 

 

4

– Difference [MR 200]

P921 (indexed)

P921 (indexed)

 

 

 

 

 

5

– Average [MR 200]

P921 (indexed)

P921 (indexed)

 

 

 

 

 

6

– OCM [MR 200]

P925

P925

 

 

 

 

 

7

– Pump Totalizer [MR 200]

P924

P924

 

 

 

 

 

P921 Material Measurement

The distance in Units (P005) or % of Span (P007) between Empty (P006) and the monitored surface.

Primary Index

Level

 

 

Values

Range: -999 to 9999 (view only)

 

 

 

 

P005 Units

Related

P006 Empty

 

P007 Span

 

 

 

P922 Space Measurement

The distance between the monitored surface and Span (P007).

Primary Index

Transducer

 

 

Values

Range: 0.000 to 9999 (view only)

 

 

 

Related

P007 Span

 

 

 

P923 Distance Measurement

The distance between the monitored surface and the transducer face.

Primary Index

Transducer

 

 

Values

Range: 0.000 to 9999 (view only)

 

 

7ML19981FB06

MultiRanger 100/200 – INSTRUCTION MANUAL

Page 219

Parameters

Page 229
Image 229
Siemens 200 P921 Material Measurement, P922 Space Measurement, P923 Distance Measurement, P001 P050 = P050 ≠