Parameters

P805 Echo Confidence

Displays the echo confidence of the measurement echo from the last shot.

Primary Index

Transducer

 

 

 

Format: x:y (view only)

Values

 

x = short (0 to 99)

 

 

 

y = long (0 to 99)

 

 

 

Related

P804 Confidence Threshold

P830 TVT Type

 

 

 

 

Use this feature to monitor the effect of transducer aiming, location, and mechanical transducer / mounting isolation.

Both short and long shot Echo Confidence is displayed. (To display this value in the

auxiliary display while the unit is running, press for 4 seconds.)

Display

Description

x:--

short shot confidence value, (long shot not used).

 

 

--:y

long shot confidence value, (short shot not used).

 

 

x:y

short and long shot confidence values (both used).

Etransducer cable is open or short circuited.

--:--

no shots were processed for Sonic Intelligence® evaluation.

P806 Echo Strength

Displays the strength (in dB above 1 uV RMS) of the echo which was selected as the measurement echo.

Primary Index

Transducer

 

 

Values

Format: 0 to 99 (view only)

 

 

P807 Noise

Displays the average and peak ambient noise (in dB above 1 uV RMS) being processed.

Primary Index

Transducer

 

 

 

Format: x:y (view only)

Values

 

x = average (-99 to 99)

 

 

 

y = peak (-99 to 99)

 

 

The noise level is a combination of transient acoustic noise and electrical noise (induced into the transducer cable or receiving circuitry). See Noise Problems in the Troubleshooting Section on page 232.