Siemens 200 instruction manual P845 Long Shot Width, P850 Short Shot Bias, P851 Short Shot Floor

Models: 200

1 282
Download 282 pages 42.81 Kb
Page 224
Image 224

Parameters

P845 Long Shot Width

Adjust the width (in ms) of the long shot transmit pulse.

Primary Index

Single Point Model

Dual Point Model

 

 

Global

Transducer

 

 

 

 

Values

Range: 0.000 to 5.000

 

 

 

 

Altered By

• P004 Transducer

 

 

 

 

 

• P841 Long Shot Number

 

Related

• P844 Short Shot Width

 

 

• P843 Long Shot Frequency

 

 

 

 

This feature is automatically altered when Transducer (P004) is altered.

P850 Short Shot Bias

Use this feature to slant the echo evaluation in favour of the short shot echo when both short and long shots are evaluated (see Shot Mode, P803).

Primary Index

Single Point Model

Dual Point Model

 

 

Global

Transducer

 

 

 

 

Values

Range: 0 to 100

 

 

 

Preset: 20

 

 

 

 

 

 

 

• P803 Shot / Pulse Mode

 

 

• P840 Short Shot Number

 

Related

• P842 Short Shot Frequency

 

• P844 Short Shot Width

 

 

 

 

• P851 Short Shot Floor

 

 

• P852 Short Shot Range

 

 

 

 

P851 Short Shot Floor

Enter the minimum echo strength (in dB above 1 uV) derived from a short shot to be considered for evaluation.

 

Primary Index

Single Point Model

Dual Point Model

 

 

 

 

 

 

 

Global

Transducer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Values

 

Range: 30 to 100

 

 

 

 

 

 

 

 

 

 

 

Preset: 50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• P840 Short Shot Number

 

 

 

 

 

 

• P842 Short Shot Frequency

 

 

 

 

Related

 

• P844 Short Shot Width

 

 

 

 

 

 

• P850 Short Shot Bias

 

 

 

 

 

 

• P852 Short Shot Range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 