ML24XXA NATIVE COMMANDS

GPIB OPERATION

SENSTL

Set Sensor Settle Percentage

SENSOR

Syntax: SENSTL <s>,<val>

s:A or B

val: 0.01 to 10%

Remarks: Sets how long the system waits for the signal to settle. The value parame- ter is only used in DEFAULT measurement sensor mode. The settling time allows some control over the tradeoff between speed, and the extent to which a measurement has settled to its final value.

Query: SENSTL? <s>

Returned

String: SENSTL <s>,<mode>

SENTYP

Return sensor information

SENSOR

Syntax: SENTYP <s>

s:A or B

Remarks: This command returns information on the selected sensor in string format: <sensor type>,<sensor serial>.

For example: Dual Diode, PBD16.

SRCMOD Source Sweep Mode

SYSTEM

Syntax: SRCMOD <mode>

mode: FREQ POWER

Remarks: Determines whether the voltage sweep applied to the V/Ghz analog input on the rear panel is interpreted as a frequency or power sweep. The x axis of the graph on the display will be labeled appropriately.

Query: SRCMOD?

Returned

String: SRCMOD <mode>

SRCSPFRQ Source Sweep Stop Frequency

SYSTEM

Syntax: SRCSPFRQ <freq_value>[units]

freq value: 10 kHz to 122 GHz

6-70

ML2430A OM

 

 

Page 157
Image 157