Anritsu ML2430A operation manual 7HP-IB Support, HP 437B Commands

Models: ML2430A

1 271
Download 271 pages 6.82 Kb
Page 250
Image 250

HP-IB SUPPORT

APPENDIX B

B-7HP-IB SUPPORT

 

The following tables list HP-IB commands for the HP 437B and HP 438A

 

 

 

power meters, and which commands are supported in the Anritsu

 

 

 

ML2430A Series power meter. Restrictions, if any, are also listed. Com-

 

 

 

mands that are not supported will be ignored.

HP 437B Commands

 

 

 

 

 

 

 

Mnemonic

 

Action

 

Supported?

 

Restrictions

 

 

 

 

 

 

 

 

 

 

 

 

 

CL

 

CAL 0 dBm

 

Yes

 

None

 

 

 

 

 

 

 

 

 

*CLS

 

Clear Status

 

Yes

 

None

 

 

 

 

 

 

 

 

 

CS

 

Clear status

 

Yes

 

None

 

CT0-CT9

 

Sensor data tables

 

Yes

 

None

 

 

 

 

 

 

 

 

 

DA

 

Set all screen pixels

 

Yes

 

None

 

 

 

 

 

 

 

 

 

DC0

 

Duty cycle OFF

 

Yes

 

None

 

 

 

 

 

 

 

 

 

DC1

 

Duty cycle ON

 

Yes

 

None

 

 

 

 

 

 

 

 

 

DD

 

Disable display

 

Yes

 

DISP OFF restrictions: Screen and

 

 

 

 

 

 

 

min/max not updated, Relative not active

 

 

 

 

 

 

 

 

 

DE

 

Display enable

 

Yes

 

DISP ON. None.

 

 

 

 

 

 

 

 

 

DF

 

Disable Display

 

Yes

 

see DD

 

 

 

 

 

 

 

 

 

DN

 

Down arrow

 

No

 

Not supported

 

 

 

 

 

 

 

 

 

DU

 

User message

 

No

 

Not supported

 

DY

 

Duty cycle

 

Yes

 

None

 

 

 

 

 

 

 

 

 

EN

 

Enter msg terminator

 

Yes

 

None

 

 

 

 

 

 

 

 

 

ERR?

 

Error query

 

No

 

Not supported

 

 

 

 

 

 

 

 

 

*ESR?

 

Read event reg

 

Yes

 

None

 

 

 

 

 

 

 

 

 

*ESE

 

Set event enable reg

 

Yes

 

None

 

 

 

 

 

 

 

 

 

*ESE?

 

Read event enable reg

 

Yes

 

None

 

ET0-ET9

 

Edit cal factor table

 

Yes

 

None

 

EX

 

Exit

 

Yes

 

None

 

 

 

 

 

 

 

 

 

FA

 

Auto average

 

Yes

 

None

 

 

 

 

 

 

 

 

 

FH

 

Average hold

 

Yes

 

None

 

 

 

 

 

 

 

 

 

FM

 

Manual average

 

Yes

 

None

 

 

 

 

 

 

 

 

 

FR

 

Set frequency

 

Yes

 

Switch to frequency cal factor source.

 

 

 

 

 

 

 

 

 

GT0

 

Ignore GET

 

Yes

 

None

 

GT1

 

TR1 on GET

 

Yes

 

None

 

GT2

 

TR2 on GET

 

Yes

 

None

 

 

 

 

 

 

 

 

 

GZ

 

Terminator

 

Yes

 

None

 

 

 

 

 

 

 

 

 

HZ

 

Terminator

 

Yes

 

None

 

 

 

 

 

 

 

 

 

ID

 

Return ID string

 

Yes

 

None

 

 

 

 

 

 

 

 

 

IDN?

 

Return ID string

 

Yes

 

None

 

 

 

 

 

 

 

 

 

KB

 

Set cal factor

 

Yes

 

None

 

KZ

 

Terminator

 

Yes

 

None

 

 

 

 

 

 

 

 

 

LG

 

Units to dBm

 

Yes

 

None

 

 

 

 

 

 

 

 

 

LH

 

Set high limit

 

Yes

 

On channel not sensor.

 

 

 

 

 

 

 

 

 

LL

 

Set low limit

 

Yes

 

On channel not sensor

 

 

 

 

 

 

 

 

 

LM0

 

Limit check off

 

Yes

 

Both high and low off as HP 437B

 

 

 

 

 

 

 

 

B-16

ML2430A OM

 

 

Page 250
Image 250
Anritsu ML2430A operation manual 7HP-IB Support, HP 437B Commands