Anritsu ML2430A operation manual System Menu, 7SYSTEM Menu

Models: ML2430A

1 271
Download 271 pages 6.82 Kb
Page 49
Image 49

OPERATION

SYSTEM MENU

4-7SYSTEM MENU

Setup

NOTE

When using the ML2430A Series Power Meter with an MA2499A or MA2499B Sensor Adapter, only Readout and Power vs. Time modes are al- lowed.

The System menus control the operating modes, display visibility, sound, rear panel functions, and battery state of the ML2430A Series Power Meter. Note that the soft keys will appear differently depending upon the operation mode selected with the Setup soft key below.

NOTE

When editing an entry in a menu, pressing the CLR key clears the digits. If in a menu screen, pressing the CLR key returns to the previous menu level.

This menu selects the operation mode, allows system setups to be saved or re- called, and provides two options to reset the system parameters to the default setup.

MODE

Select between Readout, Power vs. Time, Source Sweep and Pro-

[OPMD]

file operation modes. If only Readout is available, check the Sys-

 

temRear PanelGPIBMode setting. This setting must be ML24XX

 

for Profile, Power vs. Time and Source Sweep modes to be

 

available.

SAVE

Save the current instrument setup in one of 10 memory locations.

[*SAV

 

SYSLD

 

SYSRD

 

SYSLNM]

 

RECALL

Recall a saved instrument setup from one of 10 memory locations.

[*RCL

 

SYSLD

 

SYSRD

 

SYSLNM]

 

LINK

There are two trigger conditions saved; one for Profile mode and

[LINK]

one for Readout mode. Normally, Profile mode trigger conditions

 

can be changed without affecting the trigger conditions used in

 

Readout mode. With LINK set to ON, the Profile mode trigger con-

 

ditions are used for both Profile and Readout modes.

 

In Profile mode, the user can view what is being measured with the

 

selected trigger conditions, but only over a limited dynamic range,

 

as it only uses the two DC ranges of the signal channel. Profile

 

mode measurement rate is also limited by sweep speed.

ML2430A OM

4-21

 

 

Page 49