Paradyne 6800 manual Connecting a Local System Controller, Connecting a Remote System Controller

Models: 6800

1 351
Download 351 pages 51.03 Kb
Page 141
Image 141

Connecting the Components

Connecting a Local System Controller

The instructions that follow apply to the DATAPHONE II System Controller as well as the

ACCULINK Network Manager.

To connect a local System Controller, you will need the following materials:

035-0153-0031 cable

002-0039-0031 connector

002-0051-0031 connector

035-0152-0031 cable

To establish the cut-throughs, perform the following steps:

1.Connect the grounded end of the 035-0153-0031 cable to the next available port on the IPC-1600 card in the host processor or in the UIP.

2.Connect the other end of the 035-0153-0031 cable to the 002-0039-0031 connector.

3.Connect the 002-0039-0031 connector to the 002-0051-0031 connector.

4.Connect one end of the 035-0152-0031 cable to the 002-0051-0031 connector.

5.Connect the other end of the 035-0152-0031 cable to one of the user ports on the System Controller or ACCULINK Network Manager.

Connecting a Remote System Controller

To connect a remote System Controller or an ACCULINK Network Manager to the host processor, you will need the following materials:

035-0153-0031 cable

002-0039-0031 connector

Two DCE devices with the following characteristics:

ÐAsynchronous

ÐFull-duplex

ÐFlow control ON

ÐBit rates of 1200, 2400, 4800, 9600, 19,200 bps

002-0050-0031 connector

035-0152-0031 cable

To establish the connection, perform the following steps at the processor end:

1.Connect the grounded end of the 035-0153-0031 cable to an available port on the IPC-1600 card in the host processor or the UIP.

2.Connect the other end of the 035-0153-0031 cable to the 002-0039-0031 connector.

3.Connect the 002-0039-0031 connector to one of the local DCE devices.

6800-A2-GN22-30

January 1997

4-37

Page 141
Image 141
Paradyne 6800 manual Connecting a Local System Controller, Connecting a Remote System Controller