Bytex UMS

This section explains how to connect the Bytex UMS to the NMS host processor or the User Interface Processor (UIP). The UIP connection is restricted to cut-through only.

To connect the Bytex Switch to the host processor or UIP, you will need the following materials:

035-0153-0031 10-pin modular to 10-pin modular cable

002-0039-0031 ACU/MODEM adapter

Figure 4-28 illustrates the connection for both the host processor and UIP to the Bytex UMS for either the Bytex alerts or cut-through.

Connecting the Host Processor to the Bytex UMS

To connect a host processor to the Bytex UMS, perform the following steps:

1.Connect the grounded end of the 035-0153-0031 cable to a port on the IPC-1600 card.

2.Connect the other end of the 035-0153-0031 cable to the 002-0039-0031 ACU/MODEM adapter.

3.Connect the 002-0039-0031 ACU/MODEM adapter to a port on the Bytex UMS.

Figure 4-28. Bytex UMS Connection

4-56

January 1997

6800-A2-GN22-30