Paradyne Adding a 6510 to the 6800 Series NMS, Enter Analysis 6510 name, 15 characters max

Models: 6800

1 351
Download 351 pages 51.03 Kb
Page 256
Image 256

Loading and Restoring Software

Adding a 6510 to the 6800 Series NMS

The following procedure provides information on adding a 6510 configuration to the 6800 Series NMS.

1.To add a new 6510, you must enter a name, a port number, and a count of local terminals. Begin by selecting the appropriate entry.

TYPE: 1

PRESS: Enter

2.The system prompts for the name of the system to be added. Any combination of lowercase letters, digits, hyphens, and dots (.) may be entered.

Enter Analysis 6510 name, 15 characters max...

TYPE: ANALYSIS name

PRESS: Enter

This name displays on the 6800 Series NMS user interface as the ANALYSIS external system.

3.After entry of the system name, the system prompts for the IPC-900 port that will be used to interface with the ANALYSIS NMS.

Select port number from list [1,2,3,4,5,6,7,8]...

TYPE: IPC-900 port number

PRESS: Enter

4.After the port number is selected, the system prompts for the number of 6510 terminals attached to the ANALYSIS controller.

How many local terminals (1 Ð 6) are configured on this 6510?...

TYPE: the number of terminals physically connected to the ANALYSIS NMS

PRESS: Enter

6800-A2-GN22-30

January 1997

5-95

Page 256
Image 256
Paradyne manual Adding a 6510 to the 6800 Series NMS, Enter Analysis 6510 name, 15 characters max