COMSPHERE 6800 Series Network Management System

Figure 8-4.Port-to-Port Connections

d.To run the test,

TYPE: SPIOTEST SIOx SIOy

Where: SIOx represents the ID number of the transmitting port and SIOy represents the ID number of the receiving port.

PRESS: Enter

e.When the test is finished, you will be returned to the MS-DOS operating system. If the system hangs while running this test, you will have to reboot. Then, check to see that the driver is properly installed and the cabling is correct.

12.The third diagnostic tests the transmit circuit of a particular serial port. If the previous test produced a negative result, you can use this test to determine the functionality of the transmit circuit. To run this test, you must have a terminal connected to a port, as described in the first test. Once you have this, perform the following steps:

a.To run the test, TYPE: CTEST SIOx

Where: SIOx is the ID number of the transmitting port.

PRESS: Enter

b.When the test is finished, you will be returned to the MS-DOS operating system.