Paradyne 6800 manual Opening the Altos 5000 UIP, Installing Additional Memory on the System

Models: 6800

1 351
Download 351 pages 51.03 Kb
Page 45
Image 45

COMSPHERE 6800 Series Network Management System

Table 2-3

Altos 5000 UIP Factory- and Field-Installable Circuit Cards

Slot

Card

Memory

IRQ

I/O Address

Description

Address

 

 

 

 

 

 

 

 

 

 

 

1

Base I/O

Ð

Ð

1000Ð101F

Controls the hard disk(s), floppy

 

 

 

 

 

disk and cartridge tape drives.

 

 

 

 

 

 

 

Integral

Ð

10

1CD0Ð1CD2

Supports connection to host, full-

 

Ethernet

 

 

 

feature workstations. Incompatable

 

 

 

 

 

with Token ring card.

 

 

 

 

 

 

3

Video

A0000ÐC7FFF

±

46E8,3B0Ð3DF

Provides VGA-level graphics.

 

 

 

 

 

 

6

Proteon ProNet

Ð

10

Ð

Optional. Provides support for

 

Token Ring

 

 

 

Token Ring local area network

 

Card

 

 

 

communication with hosts and full-

 

 

 

 

 

feature workstations. Incompatible

 

 

 

 

 

with Integral Ethernet.

 

 

 

 

 

 

8

IPC-1600

E10000ÐE1FFFF

11

110Ð11F

Optional. Provides 16 serial ports.

 

 

 

 

 

 

* The IPC-1600 is required on UIP-1 with Altos 15000 host.

Opening the Altos 5000 UIP

The procedures for opening the System 5000 UIP are the same as for the System 5000 host. Refer to the section, Opening the System 5000 Host, for precise instructions.

Installing Additional Memory on the System 5000

The UIP shipped with Release 4.2 has 32 megabytes of memory. If that UIP is connected to an Altos 15000 host, it requires an additional 16 megabytes. Upgrading from a prior release of NMS may also require additional memory to be installed (see Table 2-4).

To upgrade the memory on the Altos 5000 UIP, you must have a Single Inline Memory Module (SIMM) package, part no. 555-24231-003, which contains four 4 megabyte SIMMs. Converting from prior NMS releases may require more than one SIMM package.

Install the additional SIMMs, one SIMM in each of the four memory banks on the card, immediately next to those SIMMs already installed. If the SIMMs are not adjacent to each other in each bank or a memory bank has no SIMMs installed, the processor cannot power up properly.

To install the memory on the UIP, perform the following steps:

1.If the processor is running, stop the NMS processes and shut down UNIX by following the steps in the applicable sections of Chapter 6, System Start-up and Shutdown.

2.When the message Safe to power off appears, power down the processor using the on/off switch.

3.Remove the side cover, exposing the installed boards.

2-22

January 1997

6800-A2-GN22-30

Page 45
Image 45
Paradyne 6800 manual Opening the Altos 5000 UIP, Installing Additional Memory on the System