Paradyne 6800 manual Connection Procedures

Models: 6800

1 351
Download 351 pages 51.03 Kb
Page 131
Image 131

Connecting the Components

Connection Procedures

To connect APL and DDD modems and DSUs remotely to the host processor, perform the following steps at the host processor end:

1.Connect the 035-0147-5031 cable to the octopus cable attached to the DCP/MUXi card in the host processor.

2.Connect the other end of the 035-0147-5031 cable to the local DCE device.

Perform the following steps at the remote end when connecting to a COMSPHERE device:

1.Connect the 035-0185-5031 cable to the CCIN/DCOUT jack on the hubbing device. When connecting to a 4000 Series ICC or a 3000 Series Carrier, use the CCIN jack on the carrier.

2.Connect the other end of the 035-0185-5031 cable to the remote DCE device.

Perform the following steps at the remote end when connecting to a DATAPHONE II APL or

DDDmodem or DSU:

1.Connect the 035-0184-5031 cable to the CC-OUT jack on the device.

2.Connect the other end of the 035-0184-5031 cable to the remote DCE device.

Materials Required

To connect a 4400 Series Analog Private Line modem with the Poll-Only Trib feature to the host processor, you need the following materials:

Two 035-0185-5031 cables (25-pin male to 6-pin modular)

A 4400-F1-59 871A adapter (6-pin female to 6-pin female)

Connection Procedures

To connect a 4400 Series APL modem with the Poll-Only Trib feature, perform the following steps:

1.Connect the 25-pin connector end of the 035-0185-5031 cable to the octopus cable attached to the DCP/MUXi card in the host processor.

2.Connect the other end of the 035-0185-5031 cable to the 871A adapter.

3.Connect the 6-pin end of the second 035-0185-5031 cable to the 871A adapter.

4.Connect the 25-pin end of the second 035-0185-5031 cable to the CC IN of the 4400 Series APL modem.

Ensure that the connection from the modem with the Poll-Only Trib feature runs from the

DC OUT of that modem to the CC IN of the device(s) to be polled. Set the address of any such polled device(s) one level lower than the Poll-Only tributary. Ensure that the modem using the Poll-Only Trib feature is optioned as a tributary modem. You must add the addresses of the device(s) you want to poll to the Poll-Only Trib's DC poll list by accessing the PLIST menu from the LOCAL menu on the SDCP connected to the Poll-Only Trib.

6800-A2-GN22-30

January 1997

4-27

Page 131
Image 131
Paradyne 6800 manual Connection Procedures