COMSPHERE 6800 Series Network Management System

Installing the Analysis Gateway Option (5000 Systems Only)

The ANALYSIS Gateway Option is supported by hardware and software. The IPC-900 serial card must be installed in the host processor to support the physical link between the 6800 Series NMS and the ANALYSIS NMS (see Chapter 2 for installation instructions).

The software that supports the ANALYSIS Gateway is embedded in the NMS application program loaded on the host processor. The following procedure to initialize this software is presented in three stages. The first stage involves installing and activating the software. The second stage involves configuring the software with system parameters. The third stage involves setting complimentary data rates on both the 6800 Series NMS and the ANALYSIS NMS. If, for any reason, the NMS application program must be reinstalled, the installation of the ANALYSIS Gateway must be repeated.

Installation

The installation procedure must begin with the NMS application stopped. Shut down the NMS application as described in Chapter 6. The UNIX system remains active after the NMS shutdown with a login prompt displayed.

NOTE

To cancel the installation at any time during the procedure, press the

Esc key.

1.Login, move to the installation directory, and initiate the installation program. At the login prompt,

TYPE: root

PRESS: Enter

The system prompts:

Password:

TYPE: root password

PRESS: Enter

TYPE: cd /usr/nms/RNMS/Install/A6510

PRESS: Enter

TYPE: ./Install

PRESS: Enter

2.The install script scans for th availability of interrupts, I/O addresses, and memory addresses. The system displays the message:

Installing NMS Multiple ANALYSIS 6510 support....

Searching for available interrupts...

Searching for available starting addresses....

Searching for available starting controller memory addresses...

5-90

January 1997

6800-A2-GN22-30

Page 251
Image 251
Paradyne 6800 Installing the Analysis Gateway Option 5000 Systems Only, Installation, Type root Press Enter, Password