Paradyne 6800 manual Setting Data Rates, Elapsed Time, ªSystem nameº removed from the system

Models: 6800

1 351
Download 351 pages 51.03 Kb
Page 261
Image 261

COMSPHERE 6800 Series Network Management System

4.The following counter appears:

Elapsed Time 00:00:00

The counter increments every five seconds. During this procedure, the keyboard is locked and you cannot stop the removal. For large ANALYSIS network configurations, the removal may take longer than one hour. When the process is completed, the following message appears:

ªSystem nameº removed from the system

5.The ANALYSIS Selection menu appears again (see Step 1 for menu). To remove additional 6510's, return to Step 1. To exit the procedure,

TYPE: 4

PRESS: Enter

6.When asked to display the system summary, TYPE: 4

PRESS: Enter

7.Reset the host computer. For additional information, refer to Chapter 6, System Start-up and Shutdown.

Setting Data Rates

The default data rate for the physical link between the 6800 Series NMS and the ANALYSIS NMS is 9600 bps. This rate may be changed as follows.

For the ANALYSIS controller, run syssetup following the procedures in the ANALYSIS 6510 Automated Network Management System Reference Manual.

For the 6800 Series NMS, edit the port configuration for the port connecting the ANALYSIS controller using the Edit Port Configuration (edpc) command. In the input form for the edpc command change the number in the speed field. Changing the number in this field changes the data rate.

The initial data rate is 9600. Valid data rates are 1200, 2400, 4800, and 9600. The recommended data rate for local connections is 9600 bps. For remote connections, the recommended data rate is the highest rate of your data communications equipment. If an invalid rate is entered, the system uses the initial rate set. CHANGES IN RATES DO NOT TAKE EFFECT UNTIL THE SYSTEM STOPS AND NMS IS RESTARTED. YOU MUST RESET THE ANALYSIS NMS FOR THE CHANGES TO TAKE EFFECT.