Paradyne 6800 manual NMS Commands

Models: 6800

1 351
Download 351 pages 51.03 Kb
Page 350
Image 350

COMSPHERE 6800 Series Network Management Systems

 

 

Table C-1

 

NMS Commands

 

 

 

 

Command

Name

 

Function

 

 

 

 

dsdp

Display Device Profile

 

Use this command to check the System Polling field.

 

 

 

It must be set to mux poll to permit the multiplexer to

 

 

 

be monitored for alerts and events.

 

 

 

 

eddp

Edit Device Profile

 

Use this command to set the System polling field to

 

 

 

mux poll.

 

 

 

 

dsams

Edit Alert Monitoring State

 

Use this command to check the Polling state field. It

 

 

 

must be set to polling, polling and asynch report-

 

 

 

ing, or asynch polling for control channel m2 to

 

 

 

detect faults associated with the multiplexer.

 

 

 

 

edams

Display Processing Filter

 

Use this command to set the Polling state field to

 

 

 

polling, polling and asynch reporting, or asynch

 

 

 

polling on for control channel m2.

 

 

 

 

dspf

Display Alert Monitoring State

 

Use this command to display the processing filter

 

 

 

value for each alert group of the device type specified.

 

 

 

 

edpf

Edit Processing Filter

 

Use this command to change the value of the filters

 

 

 

that define an active alert.

 

 

 

 

dsdf

Display Display Filter

 

Use this command to display the display filter value

 

 

 

for each alert group of the device type specified.

 

 

 

 

eddf

Edit Display Filter

 

Use this command to change the value of the filters

 

 

 

that define the alerts that will display on the network

 

 

 

map, network monitor, and network summary.

 

 

 

 

You should also check the Edit User Selection Criteria (edusc) command to see if the alerts you are interested in are configured for display on your individual monitor.

If you have verified that all connections and software configuration entries are correct, and that the multiplexer hardware is functioning, you should check the host processor for failure.

C-10

January 1997

6800-A2-GN22-30

Page 350
Image 350
Paradyne 6800 manual NMS Commands