Connecting the Components

Two DCE devices with the following characteristics:

ÐAsynchronous

ÐFull-duplex

ÐFlow control ON

ÐBit rates of 1200, 2400, 4800, 9600, 19,000 bps (the 19,000 bps rate requires the presence of a soft channel card [SC-1])

835-5783-0011 cable

To establish the connection, perform the following steps at the processor end:

1.Connect the grounded end of the 035-0153-0031 cable to an available port on the IPC-1600 card in the host processor or UIP.

2.Connect the other end of the 035-0153-0031 cable to the 002-0039-0031 connector.

3.Connect the 002-0039-0031 connector to the local DCE.

Perform the following steps at the remote end:

1.Connect one end of the 835-5783-0011 cable to the remote DCE.

2.Connect the other end of the 835-5783-0011 cable to the MIU attached to the DCX multiplexer.

See Appendix A, Modem Settings, for more information on optioning 3810, 3811, 3820, or 2224CEO modems for this application.

Connecting a Computer System Requiring VT100 Emulation

The purpose of VT100 terminal emulation is to allow a workstation connected to the host processor or UIP to emulate the standard Digital Equipment Corporation (DEC) VT-100tterminal via a cut-through interface.

Connecting Locally

Since this connection depends on the device you are connecting to, you will need the following materials:

035-0153-0031 cable

002-0040-0031 connector

002-0052-0031 connector

To establish the connection, perform the following steps:

1.Connect the grounded end of the 035-0153-0031 cable to an available port on the IPC-1600 card in the host processor or UIP.

6800-A2-GN22-30

January 1997

4-41