Paradyne 6800 manual Preinstallation Steps for the IPC-1600 Upgrade Card

Models: 6800

1 351
Download 351 pages 51.03 Kb
Page 49
Image 49

COMSPHERE 6800 Series Network Management System

Preinstallation Steps for the IPC-1600 Upgrade Card

To configure the IPC-1600 card, refer to Figure 2-14 and perform the following steps:

1.On the bank labeled DS1, set the memory address to E10000 with switches 1 through 8.

2.On the bank labeled DS1, set the I/O address to 110 with switches 9 through 11.

3.On the bank labeled DS2, set the IRQ to 11 with switches 1 through 8.

4.On the jumper labeled J1, check that the jumper is on Pins 2 and 3 to set the local program memory to 16 kb.

5.Follow the instructions under Field Upgrade Procedures to install the IPC-1600 card in Slot 8 of the UIP.

6.Once you have installed the card, you must run the EISA Configuration Utility to configure the System 5000's resources to match the requirements of this circuit card. For instructions, see the section entitled EISA Configuration Utility.

7.You must reload the UIP software to specify that the IPC-1600 has been installed (see Chapter 5, Loading and Restoring Software, for details).

 

Ribbon Cable Connections

 

P3 (Ports 9 – 16)

Local Program

and

P4 (Ports 1 – 8)

Memory Size Select

 

Jumper (J1)

 

DS1

DS2

 

J1

 

 

 

P3

P4

PIN 1

DS1

11 10 9 8 7 6 5 4 3 2 1

ON

OFF

110 E10000

ON OFF

DS2

8 7 6 5 4 3 2 1

IRQ 11

Push Switch to the

Indicated Position:

491-13021-02

Figure 2-14. IPC-1600 Ð Switch and Jumper Locations and Settings

2-26

January 1997

6800-A2-GN22-30

Page 49
Image 49
Paradyne 6800 Preinstallation Steps for the IPC-1600 Upgrade Card, IPC-1600 Ð Switch and Jumper Locations and Settings