Paradyne 6800 manual Preinstallation Steps for the DCP-MUXi Cards on the System

Models: 6800

1 351
Download 351 pages 51.03 Kb
Page 64
Image 64

Preparing the Processors

4.On the jumper labeled J1, check that the jumper is on Pins 2 and 3 to set the local program memory to 16 Kb.

5.Follow the instructions under Installing Circuit Cards in the System 15000 to install the IPC-1600 card in Slot 2 of the System 15000.

Preinstallation Steps for the DCP-MUXi Cards on the System 15000

To prepare the DCP-MUXi cards for installation on the System 15000, refer to Figure 2-7 and perform the following steps:

1.Remove two jumpers from each card, the first at position E32-E33 (interrupt request) and the second at position E37-E38 (transparent mode interrupt). You may store a jumper for future use, such as running diagnostics, by placing it on one pin only.

2.Verify that all other jumpers on the cards are as shown in Figure 2-7.

3.On the block SW1, set the I/O addresses as shown in Table 2-7.

Table 2-7

DCP-MUXI Ð I/O Address Switch Settings

Description

1

2

3

4

 

 

 

 

 

DCP-MUXI #1 (Slot 4)

on

on

off

off

 

 

 

 

 

DCP-MUXI #2 (Slot 5)

on

on

on

off

 

 

 

 

 

4.Follow the instructions under Installing Circuit Cards in the System 15000 to install the DCP-MUXi cards in Slots 4 and 5 of the System 15000.

6800-A2-GN22-30

January 1997

2-41

Page 64
Image 64
Paradyne 6800 manual Preinstallation Steps for the DCP-MUXi Cards on the System