COMSPHERE 6800 Series Network Management System

Type the starting I/O address and strike the ENTER key or type Q to cancel installation. Striking the ENTER alonewill select the default.

For the starting I/O address,

TYPE: 2B0

PRESS: Enter

6.The system prompts for the starting memory address:

Please enter the following system configuration information for the IPC-900 Board:

The available starting controller memory addresses for the IPC-900 Board are :

A0000 default

A2000 A4000 A6000 A8000 AA000 AC000

AE000 B0000 B2000 B4000 B6000 B8000 BA000 BC000 BE000 C0000

C2000 C4000 C6000 C8000 CA000 CC000 CE000 D0000 D2000 D4000

D6000 E0000 E2000 E4000 E6000 E8000 EA000 EC000 EE000

Type the starting controller memory address and strike the

ENTER key or type Q to cancel installation. Striking the

ENTER alone will select the default.

For the Starting memory address,

TYPE: D2000

PRESS: Enter

7.The system displays the following information before seeking verification:

**********************************************

Board Configuration:

Ports Card Type = IPC-900 Interrupt number = 5

I/O ports Starting address = 2B0

Controller Memory Starting address = D2000

**********************************************

Is this configuration acceptable? (y or n)

If these values are correct, indicate yes as follows: TYPE: y

PRESS: Enter

If the values are incorrect, indicate no as follows: TYPE: n

PRESS: Enter

to reenter the values.

8.At this point, the installation script modifies some system configuration files and rebuilds the UNIX operating system. This takes a few minutes.

5-92

January 1997

6800-A2-GN22-30

Page 253
Image 253
Paradyne 6800 manual Type 2B0, Type D2000 Press Enter